Part
Name
Description
Phenomena
Failure cause
Mechanlcal
Nolse
When
turn panel,appear cacophony
Caused by Mechanica noise of backlight unit
Ripple
Connectric circle
Causeed by between mechanism and pannel
B/L
of
f
B/L
lose action
*Connect badness between wire and electrode
B/L
dark
B/L
brightness darker than
normal
*Connect badnessShort between wire and electrode
B/L
wire damaged
B/L
wire damaged
Operation abnormal or systemic noise
B/L
wire open
Without backlight
Operation abnormal or systemic noise
B/L
shut down
B/L
shutdown in sometime
Short bitween lamp housing and wire, Because consume power too much
F/M
F/M
inB/L
,white,balck Rotundity
or wirelike
F/M in B/L
unit