background image

Outdoor  Unit

Loading of the battery

1

2

3

4

Parts and Functions

Indoor Unit

OUTLET

INLET

CONNECTING PIPING AND ELECTRICAL WIRING

DRAIN HOSE

Remote controller

Remove the battery cover;

Load the batteries as illustrated. 

2 R-03 batteries, resetting key 

(cylinder);

Be sure that the loading

is in line with th

e" + "/"-";

Load the battery,then put on the cover again.

 The distance between the signal transmission head and the rece-
iver hole should be within 7m without any obstacle as well.

When electronic-started type fluorescent lamp or change- over

wireless telephone is installed in the 

ver is apt to be disturbed in receiving the signals,

so the distance to the indoor unit should be shorter.

type fluorescent lamp or
room, the recei

Note:

Full display or unclear display during operation indicates the 

ries have been used up. Please change batteries.

If the remote controller can't run normally during operation, please 

reload several minutes later.

batte

remove the batteries and

Please be subject to the actual produce purchased the 

above picture is just from your reference

4

Hint:
Remove the batteries in case won't be in use for a long period. If
there is any display after taking-out, just press reset key.

Please be subject to the actual produce purchased the 
above picture is just from your reference

Display board

(adjust left and 

ow)

Vertical blade

r ight air fl

Air Purifying Filter

Inlet

(inside)

Emergency

 Switch

Horizontal flap

(adjust up and down air flow
  Don't adjust it manually)

Outlet

Inlet grille

Display board

1

4

2

3

5

 

Signal receiver hole

 

 

ON/OFF 

display

4

2

3

1

5

TIMER ON\OFF display

SLEEP display

 Ambient temp.display

When receiving the remote

control signal, display the set 

displayed and this room 

time the room temperature is 

temperature and in the rest

temperature is only for reference.

Note to the power failure resume:

press the sleep button ten times in five seconds
and enter function after hearing four sounds.And
press the sleep button ten times within five
seconds and leave this function after hearing

TIMER ON-OFF display

COOL\HEAT\Dry\

AUTO 

display

 two sounds.

1. Mode display

2. Signal sending display

4. FAN SPEED display

5. LOCK display
6. TIMER OFF display

TIMER ON display

LO

MED

HI

7.TEMP display

16. LOCK button

Used to lock buttons and LCD display.

25. RESET button

When the remote controller 
appears abnormal, use a sharp 
pointed article to press this button 
to reset the remote

22. HOUR button

Operation mode

AUTO

FAN

COOL

DRY

Remote controller

HEAT

1

2

3

4

5

9

10

11

12

13

14

15

16

17

22

23

24

25

19

20

21

8

18

7

6

Control the lightening and extinguishing 
of the indoor LED display board.

3. SWING  display

8.

9. QUIET button
10. HEAT button
11. COOL button
12. AUTO button
13. FAN button
14. TIMER button
15. HEALTH button

17. LIGHT button

18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button

23. EXTRA FUNCTION button

24.CANCEL/CONFIRM button

AUTO

Function: Setting and cancel to the 
timer and other additional functions.

Display 
circulated

Operation mode

Remote controller

QUITE

POWER

SLEEP

Supplemented 
    electrical 
     heating

HEALTH

Additional functions display

Healthy function is not available for some units.

Function: Air sending--- Healthy airflow 
position1--- Healthy airflow position 2
--- Restore the original flap position
--- Right & left air airflow--- A-B yard---
10 and heating symbol displayed 
simultaneously--- Sleeping--- Electrical 
heating--- Refresh air(

reserved function

)

--- Power--- Fahrenheit/Celsius mode 
conversion

1

Summary of Contents for HSU-09HEM03-R2 -

Page 1: ...A H2SM 9 9 HEK03 R2 H2SM 9 12 HEK03 R2 H2SM 9 9 HEM03 R2 H2SM 9 12 HEM03 R2 6 1 2 5 7 PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING CAUTIONS Contents 8 9 12 13 14 ndice PRECAUCIONES COMPO...

Page 2: ......

Page 3: ...display When receiving the remote control signal display the set displayed and this room time the room temperature is temperature and in the rest temperature is only for reference Note to the power fa...

Page 4: ...UTO the air conditioner automatically adjusts temperature When FAN is set the fan speed according to room In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO...

Page 5: ...after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 rises by 1 futher The unit will run for further 3 hours then stops Temp is lower than temp...

Page 6: ...directive 2002 96 CE of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and electronic products conditioning system treatment of the refriger...

Page 7: ...door unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter T...

Page 8: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or re...

Page 9: ...A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to si...

Page 10: ......

Page 11: ...O Nota para reanudar despu s de errores de alimentaci n pulse el bot n de sue o diez veces en menos de cinco segundos y acceda a esta funci n despu s de escuchar cuatro sonidos Pulse el bot n de sue o...

Page 12: ...camente la velocidad del mismo seg n la temperatura de la habitaci n REFRIGERACI N SECO En el modo SECO cuando la temperatura de la sala es inferior a la temperatura con gurada 2 C el equipo funcionar...

Page 13: ...zca una vez activada la funci n SUE O Si la velocidad del viento es baja no se llevar a cabo ning n cambio Nota Si se configura la funci n TEMPORIZADOR la funci n SUE O no se podr activar Si el usuari...

Page 14: ...Todos los productos satisfacen los requisitos de las siguientes normas europeas Directiva de baja tensi n 73 23 CEE Directiva de baja tensi n 2006 95 CE Compatibilidad electromagn tica 89 336 CEE Com...

Page 15: ...ovocar defectos Cierre la rejilla de la toma de entrada 1 2 3 4 5 Una vez cada dos semanas Sustituci n del ltro puri cador de aire 1 Abra la rejilla de la toma de entrada Sujete la rejilla de la toma...

Page 16: ...uir el aparato personalmente Conecte el cable de conexi n a tierra Precauciones ADVERTENCIA Llame al departamento de ventas asistencia t cnica si desea obtener m s informaci n acerca de la Instalaci n...

Page 17: ...blillas m viles No permita que los ni os jueguen con el aparato de aire acondicionado En ning n caso debe permitirse a los ni os sentarse sobre la unidad exterior Especi caciones El circuito de refrig...

Page 18: ......

Page 19: ...nte LUCE Controlla l illuminazione lo spegnimen to del pannello di visualizzazione LED interno 18 Pulsante ACCENSIONE SPEGNI MENTO 19 Pulsante DEUMIDIFICATORE 20 Pulsante TEMPERATURA 21 Pulsante OSCIL...

Page 20: ...ratura designata Modali t timer Velocit ventola Modalit operativa Sopra i 23 C 26 C N Sotto i 23 C 23 C N Non possibile cambiare le impostazioni della temperatura e la velocit della ventola inoltre no...

Page 21: ...e Se la ventilazione debole non modificarla Nota Se impostata la funzione TIMER la funzione di sospensio ne non pu essere impostata Una volta impostata la funzio ne di sospensione se l utente reimpost...

Page 22: ...e del Consiglio Europeo sulla limita zione dell uso di alcune sostanze pericolose nei dispositivi elettrici ed elettronici direttiva RoHS UE WEEE In conformit alla direttiva 2002 96 CE del Parlamento...

Page 23: ...stro del condizionatore 2 Staccare il ltro dell aria standard Far scorrere la rotella leggermente in alto per rilasciare il ltro quindi estrarlo 3 l i e r a s s i F ltro di puri cazione dell aria Inse...

Page 24: ...terra AVVERTENZA Non utilizzare per conservare alimenti opere d arte apparecchiature particolari per l allevamento o la coltivazione Cambiare l aria di tanto in tanto in particola re se contemporaneam...

Page 25: ...illazione Non lasciare che i bambini giochino con il condizionatore In nessun caso pu essere consentito ai bambini di sedersi sull unit esterna Speci che Il circuito del refrigerante a prova di perdit...

Page 26: ...le bouton veille dix fois dans les cinq secondes et acc dez la fonc tion apr s avoir entendu les quatre bips Appuyez sur le bouton veille dix fois dans les cinq secondes et quittez cette fonction apr...

Page 27: ...de la pi ce REFROI DISSE MENT SEC En mode SEC lorsque la temp rature de la pi ce est inf rieure de 2 C la temp rature de r glage l appareil fonctionne de fa on intermittente vitesse LENTE quel que soi...

Page 28: ...le sommeil Aucun changement si le souffle est faible Remarque Lorsque la fonction MINUTERIE est activ e la fonction de veille ne peut pas tre activ e Une fois la fonction de veille activ e si l utilis...

Page 29: ...Europ en nes suivantes Directive basse tension 73 23 CEE Directive basse tension 2006 95 CE Compatibilit lectro magn tique 89 336 CEE Compatibilit lectro magn tique 2004 108 CE ROHS Les appareils r po...

Page 30: ...t de l appareil d int rieur 2 D tacher le ltre air standard Faire glisser le bouton l g rement vers le haut pour lib rer le ltre puis l enle ver 3 Fixer le ltre de puri cation d air Placer les disposi...

Page 31: ...e fonc tionnement en d connectant le cordon d alimentation Ne pas diriger le souf e d air directement vers des person nes en particulier des enfants ou des personnes g es Ne pas tenter de r parer ou r...

Page 32: ...ies ni dans les volets de conditionnement Ne pas laisser d enfant jouer avec le climatiseur Ne jamais laisser un enfant s asseoir sur l appareil ext rieur Sp ci cations Le circuit de r frig ration est...

Reviews: