background image

1. If the supply cord is damaged, it must be replaced by the manufacturer or its

service agent or  a  similar qualied person. The type  of  connecting wire is

H05RN-F or H07RN-F.

2. If the fuse on PC board is broken please change it with the type of 

T. 3.15A/250V.

3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5.  A  breaker should be incorporated into xed wiring. The breaker should be

all-pole switch and the distance between its two contacts should be not less

than 3mm.

3

Outdoor unit

Indoor unit

A

B

Outdoor unit

Indoor unit

A

B

A

B

Outdoor unit

Indoor unit

Oil trap

Outdoor unit

Install according to

Drawing for the installation of indoor and outdoor units

To bend  a  pipe, give the roundness as large as possible not to crush the pipe ,

ƽ

and the bending radius should be 30 to 40 mm or longer.

Connecting the pipe  of  gas side rst makes  working easier.

ƽ

The connection pipe is specialized for R410A.

ƽ

Use the same method on indoor unit. Loosen the screws on

ƽ

terminal block and

insert the plugs fully into terminal block, then tighten the screws.

Insert the cable according to  terminal number in the same manner as the indoor
unit.

ƽ

If wiring is not correct, proper operation can not be carried out and controller
may be damaged.

ƽ

Fix the cable with a clamp.

ƽ

Installation of Outdoor Unit

Half union

Flare nut

Torque wrench

CAUTION

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
The standard pipe length is 5m. If it is over 7m, the function of the unit will be
affected. If the pipe has to be lengthened, the refrigerant should be charged,

according to 20 g/m. But the charge of refrigerant must be conducted by profes-

sional air conditioner engineer. Before adding additional refrigerant, perform air
purging from the refrigerant pipes and indoor unit using  a  vacuum pump,then

Spanner

Forced fastening without careful centering may
damage the threads and cause a leakage of gas.

Max.Elevation: Amax=10m

In case the elevation A is more

than 5m, oil trap shoud be

installed every 5~7m

Max. Length: Bmax=15m

In case the pipe length  B  is

more than 7m, the refrigerant

should be charged, according

to 20 g/m.

Connection of pipes

charge additional refrigerant.

Connection

If the drain-elbow is used,

ƽ

please attach it as gure. (Note:
Only for heat pump unit.)

Detach the service port’s cap  of

1.

3-way valve, the valve rod’s cap for 2-way valve

and 3-way’s, connect the service port into the projection of charge hose (Iow)

for gaugemanifold. Then connect the projection of charge hose (center) for gau-

gemanifold into vacuum pump.

Open the handle at Iow in

2.

gaugemanifold, operate vacuum pump. If the scale-

moves  of  gause (Iow) reach vacuum condition in  a  moment, check 1. again.

Vacuumize for over 15min.And check the level gauge which should read -0.1MPa

3.

(76 cm Hg) at Iow pressure side. After the completion of vacuumizing, close the

handle ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check

condition of the scale and hold it for 1-2min. If the scale-moves back in spite of

tightening, make aring work again, the return to the beginning of 3 .

Attaching Drain-Elbow

Purging Method:To use vacuum pump

Open the valve rod for the 2-way valve to an angle  of

4.

anticlockwise 90 degrees.

After 6 seconds, close the 2-way valve and make the inspection of gas leakage.

Pipe Diameter()

Fastening torque

Liquid side6.35mm(1/4")

18N.m

Liquid/Gas side9.52mm(3/8")

42 N.m

Gas side 12.7mm(1/2")

55N.m

Gas side 15.88mm(5/8")

60 N.m

Indoor unit

Outdoor unit

4G1.5mm

2

Indoor unit

Outdoor unit

)

L(

1

34

)

N(

2

4

(For: L N   )+2x0.75mm

2

Power cable:  0mm

2

 0mm

2

Connecting wiring:

HSU-09HR03/R2(DB)
HSU-12HR03/R2(DB)

Power cable:  5mm

2

HSU-09HRA103/R2

HSU-12HRA103/R2

HSU-09RUG03/R2(SDB)
HSU-12RUG03/R2(SDB)