No.0010516595

Installation Manual of Room Air Conditioner

Read this manual before installation

1.Driver

2.Hacksaw

3.Hole core drill

4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)

6.Pipe cutter

7.Flaring tool

8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or

     soap-and-water solution

11.Measuring tape

Explain sufficiently the operating means to the user

according to this manual.

A

B
C

D

E

F

G

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be
more than 2m.

A

G

more than 5cm

more than 10cm

more than 10cm

A

C

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Cement steel nail 

Screw

Plastic cap

Cover

Cushion

1

1

2

3

4

5

6

7

8

9

2

1

1

6

4

1

4

1

Number

    of

articles

Accessory parts

4X50

4X25

Pipe supporting plate

more than 10cm

more than 60cm

more than 15cm

more than 10cm

D

E

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

Attention must be paid to

the rising up of drain hose

Summary of Contents for HSU-18CRA03-T

Page 1: ...Drain hose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance betw...

Page 2: ...ptacle with enough space around Refer to drawings Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remo...

Page 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Page 4: ...ody aslant from the underside and then put it down perpendicularly 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from bac...

Page 5: ...h the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defe...

Page 6: ...wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installat...

Page 7: ...ing to the following list Piping length Additional amount 5m 7m No need 40g 10m 100g for 9k 12k 18k Push the air out of the indoor unit and piping as followes 1 Remove the valve cap on 2 way valve in...

Page 8: ...pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly expla...

Reviews: