background image

2

Operation

 Unit start / stop

1

3

2

2

Press FAN button. 

Remote controller:

Press

button

Every time the button is pressed, temp.setting

increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will 

decrease  rapidly

Select a desired temperature.

3.Fan function

2.Select temp.setting

Air conditioner is running under displayed fan speed.

When FAN is set to AUTO, the air conditioner

automatically adjusts the fan speed according to room

temperature.

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

/

Remote controller

changes as follows:

LOW

MED

HI

AUTO

Display 

circulated

   Air Flow Direction Adjustment

1.Status display of air flow

When restart after remote turning off, the remote 

         return to the previous 

2.Left and right air flow adjustment

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

adjusted to left or 

It is advisable not to keep horizontal flap at downward

position for a long time in COOLor DRY

otherwise, condensate water might occur.

at air outlet if all vertical louvers are 

right.

mode ,

controller will automatically

Note:

set swing position.

Press             button to enter additional options, when 
cycle display to        ,       will flash. And then press
enter to Left and right air flow function.

(This function is unavailable on some models.) 

COOL/DRY:

HEAT:

Initial state

Press             button to enter additional options, when 
cycle display to        ,       will flash. And then press

enter to up and down air flow function.

Press        button. For each press,changes as follows:
Remote controller:

Press        button. For each press,changes as follows:
Remote controller:
COOL/DRY/HEAT:

For each press             button fan speed 

In HEAT mode,warm air will blow out after a short 

periodof the time due to cold-draft prevention function.

When FAN is set to AUTO, the air conditioner automatically 

adjusts the fan speed according to room temperature. 

Cooling only unit do not have  displays and functions 

related with heating

 Display  Board   Remote

 Controller

        Note

COOL

DRY

HEAT

 FAN

 nothing

In DRY mode, when room temperature becomes

lower than temp.2

o

C,unit will run intermittently

at LOW speed regardless of FAN setting.

Under the mode of auto operation, air conditioner will

automatically select Cool or Heat operation according

to room temperature.

air conditioner automatically adjusts the fan speed 

temperature.

When FAN is set to AUTO, the 

according to room

In FAN operation mode, the unit will not operate in

COOL or HEAT mode but only in FAN mode ,AUTO is

not available in FAN mode.And temp.setting is disabled.

In FAN mode,SLEEP operation is not available.

 Operation

    Mode

AUTO

 nothing

Remote controller  A:

Remote controller  B:

Press             button to enter additional options, when 
cycle display to        ,       will flash. And then press
enter to FAN function.

Loading of the battery

1

2

3

4

Remove the battery cover;

Load the batteries as illustrated. 

2 R-03 batteries, resetting key 

(cylinder);

Be sure that the loading

is in line with the

" + "/"-";

Load the battery,then put on the cover again.

 The distance between the signal transmission head and the rece-

iver hole should be within 7m without any obstacle as well.

When electronic-started type fluorescent lamp or change- over

wireless telephone is installed in the 

ver is apt to be disturbed in receiving the signals,

so the distance to the indoor unit should be shorter.

type fluorescent lamp or

room, the recei

Note:

Full display or unclear display during operation indicates the 

ries have been used up. Please change batteries.

If the remote controller can't run normally during operation, please 

reload several minutes later.

batte

remove the batteries and

Hint:

Remove the batteries in case won't be in use for a long period. If

there is any display after taking-out, just press reset key.

Summary of Contents for HSU-18LXA03

Page 1: ...T3 AS24ZE1LAA AS24ZE2LAA AS24ZE1HAA HSU 18HXA03 T3 HST 24LXA13 T3 HST 24HXA13 T3 HST 18LXA13 T3 HST 18HXA13 T3 HSU 18HXA03 HSU 18LXA03 HSU 12HXA03 HSU 12LXA03 HSU 09HXA03 HSU 09LXA03 HSU 12LZE14 HSU...

Page 2: ...sending display 4 FAN SPEED display 5 LOCK display 6 TIMER OFF display TIMER ON display LO MED HI 7 TEMP display 16 LOCK button Used to lock buttons and LCD display 25 RESET button When the remote con...

Page 3: ...ft prevention function When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature Cooling only unit do not have displays and functions related with h...

Page 4: ...TIMER OFF TIMER ON OFF 3 Press button to set time It can be adjusted within 24 hours Hints After replacing batteries or a power failure happens time setting should be reset According to the Time setti...

Page 5: ...ther The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep O C 1O C Press button the remote controller will show an...

Page 6: ...rious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping then wipe off the detergent completely Indoor Body Once every two weeks 1 Open the lnlet Grille 2...

Page 7: ...try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appli...

Page 8: ...allation the power plug should be easily reached 5 The wiring method should be in line with the local wiring standard 4 The distance between the indoor unit and the floor should be more than 2m 3 If t...