Operation
Air Flow Direction Adjustment
AUTO
COOL
DRY
FAN
HEAT
2.Select operation mode
Press FAN button. For each press, fan speed changes as
follows:
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
Remote controller:
Select a desired temperature.
4.Fan speed selection
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
LOW
MED
HI
AUTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
Operation
Mode
AUTO
Display Board
Remote
Controller
Note
COOL
DRY
HEAT
FAN
nothing
In DRY mode, when room temperature becomes
lower than temp.setting about +4
o
F,unit will run
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.
air conditioner automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
intermittently
POWER/SOFT
temperature is below 60
o
F, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds. After
you hear the "Pi" sound twice, release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Pi Pi
Emergency Operation:
Emergency operation and test operation
Pi
Use this operation only when the
remote controller is defective or lost.
When the emergency operation
switch is pressed, the" Pi "sound is
heard once, which means the start
of this operation.
In this operation, the system
automatically selects the operation modes, cooling or
fan or heat, according to the room temperature.
When machine is running in emergency, the set value
of temperature and wind speed couldn't be altered;
meanwhile, it can't operate for dehumidifying or under
timing mode.
Press
button
Every time the button is pressed, temp.setting
increase 2
o
F,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 2
o
F,if kept depressed, it will decrease
rapidly
3.Select temp.setting
Clock set
Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press
change quickly. After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
or decrease 1min. If the button is kept pressed,time will
will increase
POWER/SOFT
F
CODE