10.1 Unpacking
▶
Take the appliance out of the packaging.
▶
Remove all packaging materials.
10.2 Environmental conditions
The room temperature should always be between 18 °C and 43 °C, since it can influence
the temperature inside the appliance and its energy consumption. Do not install the appli-
ance near other heat-emitting appliances (ovens, refrigerators) without isolation.
10.3 Space requirements
Required space to open the door (Fig. 10.3):
Width
in mm
Depth
in mm
Distance to wall
in mm
W1
W2
D1
D2
D3
D4
595 955
592
1105
1215
100
10.4 Ventilaton cross-section
To achieve sufficient ventilation of the appliance for
safety reasons, the information of the required ventila-
tion cross sections must be observed (Fig. 10.4).
10.5 Aligning the appliance
The appliance should be placed on a flat and solid sur
-
face. If the appliance is placed on a pedestal, strong and
fire-resistant materials must be used. Never use the
foam packing material as a pedestal.
1. Tilt the appliance slightly backwards (Fig. 10.5).
2. Set the feet to the desired level.
3. The stability can be checked by alternately bump-
ing on the diagonals. The slight swaying should be
the same in both directions. Otherwise the frame
can warp; possible leaking door seals are the result.
A low tendency to the rear eases the closing of the
door.
W2
D1
D3
D2
W1
D4
10.3
10 cm
10 cm
10 cm
10 cm
10.4
max 45°
1.
2.
3.
10.5
23
EN
10 - Installation