Service Manual
Model No:HW60-1281S/1081
Issue
Rev.
16
Error message. Water level exceeds protective value.
Error message. Motor overheat protection or is damaged.
Pull out the motor insert string, and
check the resistance of motor speed
measurer and the winding of the
motor, is it as followed?
Check the import voltage
is it between AC 220-240V ?
Replace the motor.
Replace computer board
Cut off power and check if motor
wires are connected well
Measure if resistance of motor
winding by multimeter, is it as
followed?
Pull out the wire connection of motor.
Then check if circuit is open by
multimeter
Reconnect well
Put the motor in normal temperature
about ten minutes, and then test
again. If the resistance is natural, it is
caused by overheated protection.
Then check and deal with overload,
abnormal voltage. If not, please
replace motor
Repair wires
Check if water switch hose and air
collector are jammed
put out the handle to see if the box
follow water
Without power ,connect inlet pipe to
inlet vavle,then open the tap and
observe if water is entering in
dispenser
Clean water switch hose and air
collector
put up the pip and to see if the height
is 80cm
Replace inlet valve
Summary of Contents for HW60-1081