background image

As it is sensitive to ambient temperature. Refrigerator can not operate normally 
if it is installed in environments other than those described above. Start operation 
after the environment is improved. 

Ambient temperature: 18°C to 38°C (temperature of HXC-1308/1308B: 16 ~ 32°C), 18°C to 25°C 
are optimal and air conditioning system is used as necessary. 
Ambient humidity: below 85%Rh. 
Avoid excessive dust. 
Avoid mechanical swing or vibration. 
The refrigerator shall operate at an altitude Lower than 2000m. 
Input voltage: rated voltage ± 10%

.

 

It is prohibited to install the refrigerator outdoors. Electric leakage or shock may 
be caused if the refrigerator gets wet by rainwater. 

The installation site shall meet following requirements for normal operation and best performance of 
refrigerator: 

Do not install the refrigerator in a narrow and confined space and the door of the placement room 
may not be smaller or lower than that of the refrigerator, to ensure smooth entry and exit of the 
refrigerator as well as to prevent difficulty in maintenance and damage to the stored articles due 
to not timely repair of refrigerator as the installation site is not easy to be accessed. 
The ground at the installation site shall be solid and flat. 
It is well ventilated and free from direct sunshine.
Do not share one socket with plugs of other equipment and the plug shall be securely plugged 
into the socket.  
Do not twist or compress the power line. 
If the power line needs to be extended, the extended line shall be no smaller than 3mm² in 
sectional area and no longer than 3m. 
Check the operating voltage before operation and voltage regulator appropriate for motor load 
may be applied in regions with unstable voltage. Ensure the normal input voltage stands at 
220V±10% and the power of voltage regulator is greater than 4000W.  
The refrigerator shall be grounded in a reliable manner. 
If the socket is provided with grounding wire, check if it is well grounded before operation. 
If the socket is not provided with grounding wire, a new one shall be installed by engineering 
technician. 

Do not ground the refrigerator through gas pipes, water supply pipes, telephone 
lines or lightning conductors as electric shock may be caused. 
The power plug can be accessed after installation to ensure the power line can 
be pulled out in a timely manner in emergency cases. The air vent shall be free 
from barriers. 

38

7

Product Installation

Installation environment

Installation site

Specification

HXC-358B

5 Drawers

HXC-358

Blood Bank Refrigerator 

External dimensions (W X D X H) 

mm

 

Internal dimensions (W X D X H) 

mm

 

Effective volume 

Door 

Insulating materials 

Compressor 

Shelf / Drawer

Refrigeration mode 

Outer plate / inner plate 
Condenser / evaporator 

Refrigerant 

Headlamp 

Net weight 

Temperature of temperature 

measurement box 

Rated power supply 

Rated power / current 

Alarm system 

Rechargeable battery 

720x690x1730 

620x490x1160 

358L 

Electrical heating glass door 

Hard polyurethane foam (fluorine-free) 

Totally enclosed imported compressor 

Forced Wind Cooling Circulation 

Spraying steel plate / stainless steel plate 

Fin / fin 

Computer control system 

R134a 420g 

LED   3W

158kg

4

±1

220-240V~/50Hz/60Hz

460W/3.0A

High-low temperature alarm, sensor fault alarm, power failure 

alarm,  low battery alarm and door opening alarm 

DC 12 V rechargeable battery 

Name 
Model 

Duration time of power failure alarm

48 hours (when battery is fully charged) 

I

Temperature controller 

USB function / temperature recorder 

Standard / optional 

Y

Electric shock resistance type 

Power connect style

Climate Type

Foaming Agent

Noise Level

4

43dB(A)

CP/IP

Note: Climate Type 4 means the temperature is +30

,the relative humidity is 55%.Technical 

information may vary from the appliance that you have just purchased due to technical improvements.

The loading of each shelf

Max:25kg

5 shelves / 20 baskets 

Summary of Contents for HXC-158B

Page 1: ...echnology Development Zone Qingdao 266510 P R China Web www haiermedical com Version 1st 2016 Dedicated code 0270501029 V13026 Read the Operation Manual carefully before using your appliance Keep the...

Page 2: ......

Page 3: ...ent from the figure in the manual due to product improvement The manual may be subject to changes without further notice Computer panel control digital display of temperature temperature display accur...

Page 4: ...ety Precautions Precautions for Use Product Installation Component Names Control Panel Application method Alarm Cleaning and Maintenance FAQ Refrigeration Schematic Circuit Diagram Specification 2 3 6...

Page 5: ...t to prevent personal injuries and refrigerator damage In case of flammable gas leakage such as coal gas shut off the valve of leaked gas open windows for ventilation and exhaust do not plug in or pul...

Page 6: ...gged into the socket to prevent fire Apply socket with ground wire to prevent electric shock If the socket fails to be grounded ground wires must be installed by technician Do not use the refrigerator...

Page 7: ...o children And the flammable foaming needs to be disposed by professional persons CP IP foaming materials are flammable need professional processing HXC 608B 6 Drawers HXC 608 Blood Bank Refrigerator...

Page 8: ...solvent such as gasoline Shut off the power as well as the battery switch if the refrigerator will be out of service for a long time 39 6 Precautions for Use Specification HXC 608 115V 60Hz Blood Ban...

Page 9: ...The refrigerator shall be grounded in a reliable manner If the socket is provided with grounding wire check if it is well grounded before operation If the socket is not provided with grounding wire a...

Page 10: ...ilure alarm 48 hours when battery is fully charged I Temperature controller USB function temperature recorder Optional optional Y Electric shock resistance type Power connect style Climate Type Foamin...

Page 11: ...control panel Internal fan Display panel Sensor Defrosting Control Lower temperature Upper temperature Alarm VCC GND Heating strip at the cabinet outlet Heating strip of center sill Door heating trans...

Page 12: ...the articles gradually into the refrigerator after complete examination of refrigerator 35 10 Circuit Diagram HXC 158 158B 358 358B 608 608B CN2 Cooling fan Compressor Defrosting heating strip CN2 CN...

Page 13: ...rature at one time If so the compressor may not stop for a long time with temperature reducing slowly which will reduce service life Articles must be put in batches and the temperature shall be reduce...

Page 14: ...ean data tested in the standard laboratory without noise in which the refrigerator without storage of articles is laid on the rubber pad and is steadily operated after closing the door to measure out...

Page 15: ...e for detailed information Purchasing of backup battery of the recorder Battery in the same specification and the same brand can be purchased in proper shops 9V DC In order to guarantee the reliabilit...

Page 16: ...pment and may lead to the occurrence of fault Compressor and other mechanical parts are in fully closed state and they do not need to be lubricated Clean the refrigerator Cleaning and Maintenance Comp...

Page 17: ...attery switch is on or off the remote alarm can be started The remote alarm port coordinates with the audible alarm on the refrigerator Thus the remote alarm can be stopped by pressing the key of buzz...

Page 18: ...or the refrigerator He is in charge of examining the running status of the refrigerator and making the record If the temperature inside the refrigerator is too high or too low or other abnormal phenom...

Page 19: ...ack to the normal display mode The original temperature set value 4 flickers Please do the next operation within 60s Otherwise the display panel will return to display TS SN Alarm items Buzzing Light...

Page 20: ...fter a period of Fd user parameters can be set the default value is 30 min the buzzer and remote alarm will be restarted 1Hz Continuously Buzzing 1Hz Continuously Buzzing Alarm light flashes Display b...

Page 21: ...til the pen returns to the paper At this moment the pen will pause at the most external temperature scaling line of the recording paper this scaling line does not have to be marked with temperature va...

Page 22: ...g the change of temperature in the box In order to use the disk recorder in a right and reasonable way please read the instruction bellow carefully Get familiar with your temperature recorder Adjustme...

Page 23: ...ction The computer panel has USB output function which can make use of U disk to export temperature and other test data Plug in U disk the machine begins to automatic identification and import data in...

Page 24: ...position can also be adjusted finely 3s later the scriber will slide to appointed scale according to the present perceived temperature then the calibration ends After retightening hold down bolt and...