16
Name
Transport cooler
Model
HZY-15Z
External dimensions
(W x D x H)
(mm)
520×300×270
Internal dimensions
(W x D x H)
(mm)
430×150×180
Insulating material
Hard polyurethane foam
Cooling mode
Semiconductor active refrigeration
Casing/liner
ABS/aluminum plate
Temperature control mode
Computer control system
Net weight
6kg
Range of temperature in storage/transport
2
℃
~6
℃
/2
℃
~10
℃
Rated power supply
220V (can be connected to 12V cigarette
lighting plug)
Rated power
95W
Alarm type
Overtemperature alarm, sensor fault alarm
and power off alarm
Power-off temperature keeping time
2 hours (at 28°C environmental temperature
with load)
Chargeable battery
Chargeable lithium battery
NFC clock-in function
None
Production date/Software release version
See bar code on the case body/V1
Note: Our company pays attention to technological innovation. Products are subject to upgrade
without further notice.
1
Safety Precautions
Dear users:
Thank you for use of Transport Cooler. For better understanding of this operating manual and use
of this product, and for preventing personal injury and damage to articles, please read the manual
carefully and observe the contents marked with the following signs in this manual.
Close down the gas leaking valve and open the door and windows for ventilation in case of
leakage of inflammable gas like coal gas, etc., and do not plug or pull out the power plug of the
Transport cooler. Otherwise, it may trigger an explosion and fire.
Make sure to place the Transport cooler firmly on a solid and flat ground. If the ground is not
stable or it is not properly placed, it may cause overturn of the Transport cooler or personal
injury.
Please use the dedicated power supply indicated on the nameplate of the freezer. Otherwise, it
may cause a fire or electric shock.
If the service voltage is lower than 198V or higher than 242V, it is required to additionally install
an automatic manostat suitable for electromotor load.
If it is required to lengthen the power cord, the section area of the lengthened cord must not be
less than 2mm
2
and the length shall not be longer than 3m.Otherwise, a fire or electric shock
may possibly be caused.
The power cord of this refrigerator is provided with a three-wire (grounding wire) plug, complying
with the standard 10A three-wire (grounding wire) socket. Never cut or remove the grounding
plug foot of the power cord in any case. Make sure that the power plug and socket is inserted
tightly and reliably. Otherwise, it may result in a fire hazard.
Please use power supply socket with grounding wire for fear of electric shock.
If the power socket is not grounded, make sure that grounding wire will be installed by a
professional technician.
Do not use the Transport cooler in the open air. When the refrigerator gets wet in the rainwater,
leakage of electricity or electric shock may possibly be caused.
Do not place the Transport cooler in a damp site or a place where it may be vulnerable to
sprayed water. Otherwise, leakage of electricity or electric shock may be caused due to
degeneration of its insulation.
Do not pour water onto the Transport cooler in a direct inclined way. Otherwise, it may cause an
electric shock or a short circuit.
Do not place any vessel containing water or any heavy object on the Transport cooler. If the
object falls off, it may possibly cause personal injury and the flowing water may degenerate the
insulation and further cause leakage of electricity or electric shock.
Under all conditions marked with "
", it is necessary
to refer to the documentation, so as to clarify the
nature of potential risks and any countermeasures
that must be taken.
Failure to observe the matters under the warning
signs may cause serious casualty accident.
Conduct or operation that
must be forbidden
Conduct or operation that
must be observed
Failure to observe the matters under the caution
signs may cause casualties or freezer damage and
associated property loss.
Warning
Caution