52
10.3 Panel failure
Failure Mode
Part Name Description Phenomena
Failure
cause
V B/D
Vertical bar
V Dim
Virtal gray
line
V L/D
Vertical color
line(light or
dark forever)
H B/D
Horizontal
bar
H Dim
Horizontal
gary line
TCP
H L/D
Horizontal
line(light or
dark forever)
Block Defect :TCP cracking or cracking
Dim or L/D :TCP Sunken
:TCP lead cracking
:ACF bonding short
:Awful environment and something electric enter into
LCD
:Mis-align between TCP and Panel
:Panel failure
:TCP failure
Failure Mode
Part Name Description Phenomena
Failure
cause
Panel or
Polarlzer
Dot Defect
Bright dot dark
dot in panel
Incoming Inspection Standard
Summary of Contents for L40R1
Page 8: ...8 3 2 2 Connector definition Power connector CNA1 MTk5380 ...
Page 21: ...21 Power source Removing the table stand and installing a wall mount bracket ...
Page 31: ...31 4 Channel 5 Gamma 6 BackLight ...
Page 32: ...32 7 Function ...
Page 33: ...33 8 BLOCK DIAGRAM AND CIRCUIT DIAGRAM 8 1 BLOCK DIAGRAM 8 2 CIRCUIT DIAGRAM MTK5380 ...
Page 49: ...0090403331 ...
Page 50: ...50 10 TROUBLE SHOOTING GUIDE 10 1 Simple check 10 1 1 LCD is not bright 10 1 2 No picture ...