defrosting process, this is a normal phenomenon
while defrosting.
ensure each seat
to stress for
avoiding
resonance.
8-2. Fault diagnosis and display method
Under lock mode, please press “Refrigerator” for a long time and continue to click “Freezer”
for five times at the same time, so that can enter/exit fault code display mode. Fault code
display in the temperature display area. In the fault display state, press “Lock/unlock” every
time, the current fault code will display by recycle. If refrigerator has no fault, it will exit fault
mode automatically.
Fault
No.
Fault mode
Code
display
area
Code
Check method
Remarks
Sensor
Resistance
Rs(K
Ω
)
Temp.
Value
T(
℃
)
1
Temp. sensor fault Ref. Temp. ar F2
Rs
≤
0.094
or Rs
≥
235
T=117.3 or
T=-55.9
Refrigerator
2
Ref. sensor
/ Ref. R1 fault
Ref. Temp. ar F3
Rs
≤
0.094
or Rs
≥
235
T=117.3 or
T=-55.9
Refrigerator
3
Frz. sensor fault
Frz. Temp. areF4
Rs
≤
0.297
or
Rs
≥
750
T=75 or
T=-70.17
Freezer
4
Frz. defrosting
sensor fault
Frz. Temp. areF6
Rs
≤
0.297
or Rs
≥
750
T=75 or
T=-70.17
Freezer
5
Communication fau Ref. Temp. ar E0
No communicate between
display panel and main
control panel for two minutes
/
6
Frz. fan motor fault Frz. Temp. areE1 /
/
/
7
Ref. fan motor fault Ref. Temp. ar E2
/
/
/
8
Frz. defrosting fault Frz. Temp. areEd
Defrosting heater work for
more than 70 minutes, Tem
of
defrosting sensor do not
reach 7
℃
/
Display priority
1. Display priority of freezing temperature display area:
F6
〉
FC
〉
Ed
〉
Er
〉
F4
〉
gear set
〉
Temp. display
2. Display priority of refrigerator temperature display area:
E0
〉
E1
〉
E2
〉
E3
〉
Eh
〉
F2
〉
F3 > F8 > F1 >F9 >F5 > F7 > FA >Fb> gear set
〉
Tenp
display