background image

Checker

Certificate of Quality

Sea Elephant 

Rev

01

specific  number

0040570098

           

 Solar water heater

Please read this manual carefully before use
Please keep this manual for future reference. 

                 

User s  Manual

`

PJF2-150W

BRF2-150W

Summary of Contents for Sea Elephant BRF2-150W

Page 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Page 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Page 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Page 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Page 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Page 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Page 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Page 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Page 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Page 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...

Reviews: