background image

9

6

Installation

Installment of water-storing tank

Water storing tank  is a standing tank. Based on customers' requests, 
ascertain specific installment position, and place water-storing tank

then 

connect the tempreture and pressure valve,cold water-inlet,hot water-
outlet,please see Fig.1-Fig.2. based on the distance between solar stage 
and tank, machining one corrugation pipe, and connect the circulating water-
exiting and the below water-inlet of the solar stage. Then connect the sensor 
of tank and inside wire to the solar stage, Pay attention that the distance 
between solar stage and tank should not be over 0.6m

please see Fig.1-

Fig.2. 

Connection of pipeline

To measure the distance between water-inlet of collector and the tee joint of 
expanding tank, water-outlet of collector and circulating water-inlet of tank, 
solar stage and circulating water-outlet of tank, To cut pipes according to the 
measured size, to cover the heat preservation layer, and to connect water-
inlet of collector, the tee joint of expanding tank, water-outlet of collector and 
circulating water-inlet of tank, as well as the solar stage and circulating 
water-outlet of tank,please see Fig.1-Fig.2. Pay attention that the connection 
of circulating pipeline should avoid the opposite alternative. The connection 
of pipe parts should be proper and firm, and the heat preservation materials 
should be covered perfectly. Pay attention that the probe of the sensor is 
placed properly. Installment of pipeline should be artistic and neat.

Connection of Single direction valve

Fix the Single direction valve 1 on the cold water-inlet of tank,then connect 
the Single direction valve1 to the water supply;Fix the Single direction valve2

Ò £ ¿ Ø Æ ÷ Ê ¹ Ó Ã ¼ ò ½ é

Use method

On the solar stage pothook. Pay attention that the place of the solar stage 
muse be nicety(please see Fig.6), and power of water pump should be 
adjusted to the third grade.
Note: To avoid to put other things on the solar stage. And to avoid that water 
spatter the pump directly,or the result is serious.

Fig.5  Installment sketch map of PJF2-150W 

Fig.6 Solar stage pothook fixing size(unit:

mm)

 L4(Double color)--- when the green point in the icon is on, it tells that the 
system is in the intellectual heating mode. When the red light is glistening, it 
tells that the system in electrical heating and when it reaches the mounted 
temperature, the green point will be on   constantly.
L5(Yellow)---when the character is on, it tells the temperature of  water-
storing tank.
L6(Red)--- when the character is on, it tells the temperature of water-exiting 
temperature of collector equipment.

Í ¼ È ý     ¼ ¯ È È Æ ÷ µ Ä ° ² × °

Use methed

For the first use after installation, due to there's no water within the tank, first 
the cold water inlet valve and mixing valve must be opened. Close the mixing 
valve when water flows out continuously from the showerhead or other outlets 
(the tank is full). Check connections are free of water leakage, and insert the 
power plug. 

1. introduction of basic working mode

A.Solar energy heating: this function adopts the temperature difference 

between water-exiting temperature of collector equipment and that of water--
Storing tank to control the running of water pump. It transfers solar energy 
absorbed by collector equipment to hot water in water-storing tank for storage. 
In cases when the machine is turned on, press the mode key to enter the solar 
energy heating mode (Note: the first time the system is electrified, this mode 
can be entered). The green point is in the working indication icon is on in the 
solar energy heating. Press the setting key and   you can adjust the clock and 
choose temperature difference value (10

 or 15

, the default value is 15

of the water pump running. When the starting conditions for water pump are 
reached, then the water-exiting temperature of collector equipment 

20

Meanwhile, when temperature difference between water-exiting of collector 
equipment and water in water-storing tank is higher than the set value (10

 

or 15

), water pump will automatically start and run at full speed. When the 

temperature difference is less than 4

, water pump will automatically stop.

B.Instant heating: in cases when the machine is turned on, press the mode key 

to enter the instant heating mode. The green point in the working indication 
icon of this heating is on. To automatically start electrical heating according to 
the preset 65

 of the system and the red point glistens. Press the setting 

mode and you can set water temperature, whose scope is 30

-75

. When 

the preset temperature is reached, the electrical heating will stop 
automatically. The working mode will automatically leap from this mode to the 

Introduction for the controller

Summary of Contents for Sea Elephant BRF2-150W

Page 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Page 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Page 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Page 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Page 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Page 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Page 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Page 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Page 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Page 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...