Procedure
-
>
Test Program
No.
Display
on the
screen
Process
0
8:88
Initialization
1
0A
Inlet Valve
2
09
Washing Pump
and Dispenser
3
08/
tempera-
ture
value
Heating Element
4
07
Drain Pump
5
06
Pause
6
05
Inlet Valve
7
04
Washing Pump
8
03
Pause
9
02
Washing pump
10
01
Drain Pump and
Regeneration
Valve
11
F*
finish
Procedure of Test Program
(for models controlling water filling by flowmeter)
Drain for 30s.
Pause for 10s.
Open inlet valve and feeds with 3.6L water
Description
Power on, stand by
Open inlet valve and feeds with 3.6L water.
Buzz one sound, stop, and stand by.
Dispenser will act once and washing pump will run for 60s in this step.
Run washing pump and heating element until the water temperature
reaches 57℃. Then the machine will pause.
Press Program button to jump into the next step.
Open regenaeration valve and drain for 30s.
Run washing pump for 2 mins.
Pause for 5s.
Run washing pump for 1 min.
-