Assembly
Information brochure · H-50.2 system components
V02R00 · 1134319 · 2022-11
29
Overhang of the fall protection rail on
the ladder rung
Fig. 23: Dimension for overhang of the fall pro-
tection rail on the ladder rung
The minimum overhang of the H-50.2 fall pro-
tection rail, measured from the middle of the
ladder rung, must total 80 mm. The maximum
overhang of the H-50.2 fall protection rail,
measured from the middle of the ladder rung,
may not exceed 140 mm.
These specifications refer to the first rung after
the beginning of the rail or end of the rail at the
top and bottom respectively.
IMPORTANT!
The fall protection rail must be attched to the access ladder on the first rung after the beginning
of the rail or end of the rail at the top and bottom respectively.
The attachment intervals in between must be adhered to, even if they are smaller than the max-
imum specifications permitted. A replacement rail section within the access route must be in-
stalled on the ladder at a minimum of two attachment points.
An access route must exhibit a minimum of 5 attachment points in any case. This must also be
ensured when the access route consists of only one fall protection rail.
Properly installed sections of fall protection rail can be considered a continuous fall protection
rail.