hs dock
Maintenance
Order h49 7144.907-333
81
11.4 Cleaning
WARNING
Eye injuries and cuts caused by failure to wear
protective clothing during cleaning operation!
Never use compressed air to clean the product.
Also wear the following items of personal protec-
tive equipment, in addition to the basic equip-
ment:
NOTE
Damage to seals caused by the wrong solvent!
To clean the product, never use a solvent that at-
tacks and damages the sealing elements in-
stalled. Those installed sealing elements can be
made of NBR, Viton and PUR materials.
To clean the product, never use a solvent that
contains ester, nor a polar solvent.
1. Remove the clamping device from the product [see »Re-
moval of clamping device« chapter].
2. Remove the product from the machine [see »Removal
of the product« chapter].
3. Clean all surfaces on the product that can be accessed
without disassembly, using an ester-free, non-polar
cleaning agent and a soft, lint-free, tear-resistant cloth,
wiping away all oil and grease residue and checking for
visual signs of damage.
11.5 Visual inspection
Perform a daily visual inspection of the product to identify
any damage to the product at an early stage.
Check the product for cracks and damage.
A check is also required to ensure that all fixing screws are
tightened down.
If damage is detected, the relevant components must be ex-
changed immediately for genuine spare parts from the man-
ufacturer.
Complete cleaning of the product is required if heavily soiled
[see »Cleaning« chapter].