MANDO Adapt T212
Faults
Order h49 7144.907-333
103
13 Faults
The following chapter describes possible causes for faults,
and the work involved in remedial action.
If multiple faults occur, shorten the maintenance intervals in
accordance with actual load levels.
Contact the manufacturer if faults occur that cannot be rem-
edied by following these instructions [see »Contact« chap-
ter].
13.1 Procedure with faults
This applies in all cases:
1. With faults that constitute an immediate danger to peo-
ple or capital equipment, press the Emergency Stop but-
ton on the machine tool immediately.
2. Establish the cause of the fault.
3. If troubleshooting requires work to be conducted in the
danger area, switch the machine tool into set-up mode.
4. Notify the person on location of the fault immediately.
5. Depending on the type of fault, get it remedied by au-
thorized and appropriately skilled specialists.
INFORMATION
The troubleshooting table in the following section pro-
vides information about who is authorized to remedy
a given fault.
6. In the event of a fault not caused by the product, the fault
may be caused by something close to the machine tool.
For this, refer to the operating instructions of the ma-
chine tool.
13.2 Fault table
Fault
Possible cause
Remedial action
Remedied by
Defective axial
strokes in the ad-
aptation clamping
device
Dirt in the parts in
the power flow
Remove and clean the clamping
element and, if necessary, re-
move, dismantle and clean the ad-
aptation clamping device
Skilled special-
ist
Incorrect coupling
position
Check the coupling position and
align with the adaptation clamping
device
Clamping element
cannot be
swapped in or out
Defective axial
strokes in the ad-
aptation clamping
device
See fault »Defective axial strokes
in the adaptation clamping de-
vice«
Adaptation clamp-
ing element cannot
Defective axial
strokes in the basic
clamping device
See operating instructions for the