MANDO Adapt T212
Installation
62
Order h49 7144.907-333
C
Screw plug
D
Changing part variant, direct screw connection
E
Changing part variant central axial screw connection
E1 Fixing screws, changing part variant, central, axial screw connec-
tion
DANGER
Serious injuries caused by workpieces being
ejected centrifugally if the coupling ring is not se-
cured properly!
Always secure the coupling ring with the rotary
extractor ring / a changing part.
If the front thread on the mandrel body is used to
install a changing part, always secure the cou-
pling ring with the rotary extractor sleeve / another
changing part.
The changing parts, such as the workpiece end-stop, can be
installed in different ways.
If necessary, in addition to these operating instruc-
tions, you should also read and follow the operating
instructions for the relevant changing parts.
1. As described in the »Preparation of the machine for in-
stallation« chapter, prepare for the following steps.
2. Move the clamping device into release position.
INFORMATION
If necessary, the changing part is positioned. Position-
ing can for example be performed by marks, or a cy-
lindrical pin and a bore or a groove.