MANDO Adapt T212
Removal
92
Order h49 7144.907-333
WARNING
Serious injuries caused by the coupling ring being
ejected centrifugally after incorrect installation!
The coupling ring must never be installed without
the rotary extractor sleeve / the workpiece end-
stop.
If installation / removal work is interrupted, either
remove the coupling ring [rotary extractor sleeve
/ workpiece end-stop is not fully installed], or the
rotary extractor sleeve / the workpiece end-stop
must be fully installed before the interruption.
INFORMATION
Depending on size, positioning marks can be applied
to the coupling ring and the product.
10. Place the coupling ring around the coupling on the prod-
uct so that the pins in the product are aligned with the
bores in the coupling ring, paying attention to the marks
if necessary. For this, the coupling ring must engage in
the groove in the coupling. Keep the coupling ring
closed.