MANDO Adapt T212
Maintenance
Order h49 7144.907-333
99
6. Conduct a function test of the coupling area of the prod-
uct [see »Installation of the product« chapter].
Installation of the coupling cover
1. Immerse one third of the end of the coupling slider
springs in lubricant.
2. Set up the coupling slider springs obliquely in the cou-
pling slider grooves with the help of the lubricant adher-
ing to them.
3. Install the coupling cover centrally and horizontally with
its pins aligned with the grooves in the coupling sliders.