ms dock
Technical data
Order h49 7144.907-333
21
3.4 Speed
The product was designed for stationary operation.
WARNING
Serious injuries caused by imbalance during con-
tinuous rotational operation!
Do not operate the product in continuous rotation.
Rotate the product at no more than max. 60 rpm.
From all of the maximum speeds indicated for the
combined products, always remain at the lowest
of those maximum speeds.
3.5 Conversion of actuating torque to actuating force
To find the right settings, you need to convert from actuating
torque to actuating force or vice versa.
3.5.1 Nomenclature
Brief des-
ignation
Unit
Explanation
𝐹
𝑎𝑥
𝑘𝑁
Axial actuating force
𝐹
𝑎𝑥 𝑚𝑎𝑥
𝑘𝑁
Maximum axial actuating force
𝑀
𝑁𝑚
Actuating torque
𝑀
𝑚𝑎𝑥
𝑁𝑚
Maximum actuating torque
Table 2:
Nomenclature for conversion of actuating torque to actuat-
ing force
3.5.2 Calculation
The following formula should be used to determine the actu-
ating torque that needs to be set to achieve a defined level
of actuating force:
𝑀 =
𝑀
𝑚𝑎𝑥
∗ 𝐹
𝑎𝑥
𝐹
𝑎𝑥 𝑚𝑎𝑥
INFORMATION
The maximum actuating torque
𝑀
𝑚𝑎𝑥
and the maxi-
mum actuating force
𝐹
𝑎𝑥 𝑚𝑎𝑥
can be taken from the
»General information« chapter.
The following formula should be used to determine the actu-
ating force present at a given actuating torque setting:
𝐹
𝑎𝑥
=
𝐹
𝑎𝑥 𝑚𝑎𝑥
∗ 𝑀
𝑀
𝑚𝑎𝑥
INFORMATION
The maximum actuating torque
𝑀
𝑚𝑎𝑥
and the maxi-
mum actuating force
𝐹
𝑎𝑥 𝑚𝑎𝑥
can be taken from the
»General information« chapter.
Summary of Contents for ms dock
Page 1: ...Operating instructions incl installation manual ms dock EN...
Page 57: ...ms dock Removal Order hotline 49 7144 907 333 57 6 Remove the product from the machine table...
Page 68: ...ms dock Annex 68 Order hotline 49 7144 907 333...
Page 69: ...ms dock Annex Order hotline 49 7144 907 333 69...
Page 71: ...ms dock Order hotline 49 7144 907 333 71 U Unpacking 29 W Warranty 10...