ms dock
Use
Order h49 7144.907-333
47
8.6 Actuation of the clamping device
A
Actuating screw
B
Clamping device
C
Actuating key
Special aids required:
Actuating key
DANGER
Serious injuries caused by parts being ejected
centrifugally if level of workpiece clamping is in-
sufficient!
Never completely use up the total stroke of the
product.
WARNING
Serious injuries caused by projectile ejection of
an actuating wrench!
Only ever use the original actuating wrench!
Immediately after use, take the actuating wrench
out of the product and remove it from the working
area of the machine.
If the self-ejector function of the actuating wrench
does not work, or is impaired, it must not be used
until after a new spring has been installed.
Summary of Contents for ms dock
Page 1: ...Operating instructions incl installation manual ms dock EN...
Page 57: ...ms dock Removal Order hotline 49 7144 907 333 57 6 Remove the product from the machine table...
Page 68: ...ms dock Annex 68 Order hotline 49 7144 907 333...
Page 69: ...ms dock Annex Order hotline 49 7144 907 333 69...
Page 71: ...ms dock Order hotline 49 7144 907 333 71 U Unpacking 29 W Warranty 10...