3. When daylight threshold is set to “Disable”
,
hold time is set to 5s/90s/5min/10min; hold time before sterilamp turn on is set
to 5s/10min
,
work time is set to 30min/1H/2H
;
Sterilamp OFF after the work
time until the next round start
when the sensor detect
movement.
Sterilamp will turn into work
mode when sensor don’t
detect any movement after
people leave. Hold time could
be set to 5s/10min.
LED light ON when people
approach
(
sensor detect
movement).
Sterilamp work time could be
set to 30min/1H/2H.
4. When daylight threshold is set to 2lux/10lux/50lux/Disable
;
Sterilamp work time is set to “+∞”
,
sterilamp won’t turn off
until the sensor detect movement
;
Sterilamp will keep ON until
the sensor detect movement,
then turn off. Followed by
recycling.
Sterilamp turn off when
detect movement, the sensor
will control the LED light to
be ON/OFF based on the
daylight threshold setting
(Refer to point 1/2/3 above).
Sterilamp keep ON when no
movement detected.
If LED light ON when people
approach, the light will keep
100% brightness during hold
time after people leave.
Otherwise sterilamp start to
work after people leave.