background image

Sensor & Intelligent Control

LUX OFF

LUX ON

1. Standby period is +

2.Standby dimming level is on 10%
20% or 30%;

3. Daylight threshold is on 2Lux, 
10Lux or 50Lux.

Daylight Priority

Dusk/Dawn sensor:

Dual-PD technology brings a fully automatic dusk/dawn sensor which can tell the difference between natural 
light and LED light, to ensure the light will be off when needed.

With Daylight priority function, HD06VCRH 3 is able to differentiate 

artificial light brightness from natural light after installed inside the 
fixture, 

and automatically turn off light when ambient brightness exceeds preset 
lux level.

Precondition of Daylight priority:

Natural Light

Light off automatically

light on automatically

Light automatically on 
when ambient brightness 
is lower than preset lux 
level.

With insufficient 

ambient brightness, 
light dims to 100% 
when motion detected 

Light dims to standby level 
if no motion detected after 
holdtime.

Light off when ambient lux 
level is higher than preset 
lux amount.

Performance

1.Application——Lux on/off

Stand-by 

period

Summary of Contents for HD06VCRH 3 (HN074)

Page 1: ...20 30 50 Hold Time 5s 30s 1min 3min 5min 10min 20min 30min Technical Data Operating Voltage 10 5 15V DC Operating Current 30mA 5 Output DIM 0 10V Stand by power Microwave Power 0 3mW Microwave Frequen...

Page 2: ...ns Highest mounting height is 15m This gure indicates the maximum distance at the highest mounting height with 100 sensitivity 0 5 1 0M S Ceiling Mounted Wall Mounted Mounting Height Mounting Height W...

Page 3: ...o differentiate arti cial light brightness from natural light after installed inside the xture and automatically turn off light when ambient brightness exceeds preset lux level Precondition of Dayligh...

Page 4: ...s light ON when motion gets detected The sensor keeps light ON for holdtime period after motion leaves The sensor turns OFF light automatically after the holdtime 4 Corridor Function Bi level Dimmable...

Page 5: ...ay from the driver to avoid interference genera tion and lamp ashing 6 Wiring must be strictly in accordance with the wiring diagram to avoid short circuit Application Environment 1 Suitable for indoo...

Page 6: ...OFF Reset Auto Mode Start Memory Apply Test 2s Remote Keys Function Performance Auto Mode Reset Start ON OFF Memory Detection area Hold time Stand by period Stand by dimming level Test mode Press Aut...

Page 7: ...Choose necessary functional buttons of all the zones detection area holdtime standby dimming level standby period and daylight threshold 5 MEMORY button to keep the program inside the remote 6 APPLY b...