MB6 (6-Slot) Chassis
MB6 Installation
MB6 and MB21 Multichannel Chassis Installation Guide, v2.0, Issue 01
11
2.
Locate DC Power IN connectors (
+
and
-
) on the back of the chassis (see
3.
Connect the chassis ground wire to the ground lug on the back of the chassis.
4.
Adhere to your organization’s policy on the gauge of the ground wire (12 AWG, insulated, stranded) and the
number of crimps on the lug.
5.
Wrap each wire around the screw on the connector, and then tighten the screw firmly.
NOTE
Connect the screw marked
+
to a +28 VDC power source and the screw marked
-
to the neutral
wire. The maximum width of the terminal lug is 0.32 inches (8.13 mm). The minimum wire gauge is 16
AWG.
Figure 5: F-MB6X-RAC Chassis PDU Connections
The PSU Status LEDs will turn green indicating that the chassis is powered up.
In the front of the chassis, the Status LEDs will start blinking green, indicating that the encoders/decod-
ers/gateways are booting up.
6.
Wait until the Status LEDs stay solid green, indicating that the chassis is ready for operation.
To begin configuring the unit, open the Web interface and log in. Please refer to the encoder, decoder, or gateway
product documentation for details.