After these steps, the process of putting the water heater into operation is the same as if a new
water heater was put into operation.
Active anode
As a supplementary accessory, the hot water tank is equipped with an active anode to protect it against
corrosion. The life expectancy of the active anode depends on the conditions of water and operation. The
state of the anode has to be checked during periodic maintenance measures targeting scale removal or at
least in every second year.
The date of repeated check is defined by the repair technician. If the diameter of the anode shrinks to 10 mm
at any points, it has to be replaced. The replacement of the active anode can only be performed by a
contracted service shop (see the commercial warranty!).
After the replacement of the active anode, its earthing has to be set according to its original state. It is
extremely important to ensure a good metal contact between the active anode and the earthing screw
.
IN CASE OF NEGLECTING THE ABOVE INSTRUCTIONS THAT CAUSES DAMAGE TO
SAFETY AND USAGE FEATURES OF THE HOT WATER TANK, YOU LOSE YOUR
GUARANTEE AND WARRANT RIGHTS.
WATER DRAINAGE IN CASE OF DANGER OF FROST
The water has to be drained from the water heater absolutely, if the appliance stays out of operation
at a location, which is exposed to danger of frost. In order to ensure this, the followings have to be
performed:
1. The water heater should be annealed.
2. The inflowing cold water faucet should be closed. .
3. The water heater should be drained with the help of
the safety blow-off button (turning the operation button).
Summary of Contents for IDE75F ErP
Page 2: ...2 44...
Page 8: ...8 44 RU IDE F IND F 1 200 2 75 200 IDE S IND S 1 50 2 70 3 6 1 IDE F IND F 2 IDE S IND S 7...
Page 9: ...9 44 RU 6 1 2 1 3 4 5 MSZ172 1 3 65...
Page 10: ...10 44 RU 1 2 1 3 IDE F IDE S 10...
Page 11: ...11 44 RU 1 2 3...
Page 37: ...37 44 HU RU EN DE FR CS RO 1 2...
Page 40: ...40 44 HU RU EN DE FR CS RO IDE F IDE S 3 4 IND F IND F 5...
Page 44: ...44 44 1221111750 02...