35 / 40
Hakki Pilke 38 Pro
Translation
Version 3
8.
Failures and remedial measures
Failure
Cause
Remedial measure
The
splitting
force
is
insufficient to split the log.
1. Log sideways
2. Machine overheated
3. Adjustment of the speed valve
faulty
1. Remove and replace
2. Check the hydraulic oil
temperature in the
machine and the filter
condition (see Section
5.3).
3. Contact the retailer.
The in-feed conveyor belt does
not move.
1. The belt is too loose or is not
properly aligned.
1. Tension or adjust the belt
according to the instructions
in Section 5.4.1.
The output conveyor does not
move.
1. The belt is too loose.
1. Tighten the belt according to
the instructions in Section
5.4.2.
.
The cutting motion does not
fully cut the log.
The path of the saw bar is
incorrectly adjusted.
Lower the path of the saw
bar.
The saw chain does not
properly sink into the wood.
1. The saw chain is dull.
2. The saw bar is crooked.
1. Sharpen or replace the saw
chain.
2. File the bar to make it
straight.
The machine starts but none of
the
functions
work.
The
machine makes an abnormal
noise.
The electric motor runs in the
wrong direction.
See Section 3.2.2.
The electric motor does not
start.
1. The machine makes a loud
noise but does not start.
2. The input cable is faulty.
3. The thermal relay has tripped.
1. The gear fuse has blown.
Replace it.
2. Replace the cable.
3. Acknowledge the thermal
relay by pressing the red
Stop button of the starter
behind the machine.
The motor tends to stop, and
the thermal relay is easily
tripped.
The thermal relay is broken or
incorrectly adjusted.
Contact the retailer.
Cutting blade will not start
rotating
1. The machine guard is
open.
2. 12 V power cable is not
connected.
1. Close the guard.
2. Connect the power
cable.