45 / 47
Hakki Pilke 50 Pro
Translation
Version 1-2018
5.12.
Failures and remedial measures
Failure
Cause
Remedial measure
The
splitting
force
is
insufficient to split the log.
1. The log/splitting blade is in an
incorrect position.
2. The splitting force is not great
enough.
3. Pressure boost ends.
1. Fix the position of the log/splitting
blade.
2. Contact the retailer.
3. Return the splitting to the
starting position and restart.
The in-feed conveyor belt
does not move.
1. The belt is too loose.
1. Tension the belt according to the
instructions in Section 5.4.1.
The out-feed conveyor belt
does not move
1. The belt is too loose (the lower
drive roller moves).
2. The lower drive roller is jammed
and does not move.
1. Tighten the belt according to the
instructions in Section 4.4.
2. Disconnect the machine from the
power source and remove the
obstruction.
The saw chain does not
properly sink into the wood.
1. The saw chain is dull or cuts to
the side.
2. The saw bar is crooked.
3. The saw chain is not supplied
with sufficient oil.
1. Sharpen or replace the saw chain.
2. File the bar to make it straight.
3. Increase oil feed.
The machine starts but
none of the functions work.
The machine makes an
abnormal noise.
The electric motor runs in the
wrong direction.
See Section 3.2.2.
The electric motor does not
start.
1. The machine makes a loud
noise but does not start.
2. The thermal relay has tripped.
3. Starter fuse triggered.
4. The input cable is faulty.
1. The gear fuse has blown.
Replace it.
2. Reset the thermal relay with the
starter’s stop button.
3. Disconnect from the power
source and check the starter
relay.
4. Replace the cable.
The electric motor tends to
stop, and the thermal relay
is easily triggered.
1. The thermal relay is broken
or incorrectly adjusted.
Some other problem?
1. Contact the retailer.
The cutting
or
splitting
function does not work.
1. The machine guard is open.
1. Close the guard completely.
The sawdust blower is
jammed.
1. There is a chip or
obstruction in the sawdust
blower.
1.
Clean the blower’s motor.
The machine’s electrical
control does not work or
works unreliably (sawing
button, splitting button)
1. In a PTO machine, the 12 V
plug is not connected to the
tractor (in an electrical
model, the 12 V plug is not
connected to the machine)
2. Guard open or sensor fault
3. Connection or grounding
fault in the tractor.
4. Burnt fuse in the 12 V relay
box.
1. Connect plug. See Section
3.2.1
or
3.2.2
2. Fully lower the guard and
check sensor operation
(Figure 56).
3. Check the connections
4. Determine the cause of the
burnt fuse, and replace the
fuse after repairs.
The saw bar is not lowered
fully when the cutting button
is pressed.
1. Saw dust or debris under the
saw drive end
1. Clean