VACUUM
MODE
POWER
TIME
AIR
TEMP
AIR CONTROL
OFF
ON
Press the button once.
Press the or button.
Temperature
setting section
Press and hold the button
for more than one second.
Press the button once.
Press the button once.
UP
DOWN
Press the or button.
UP
DOWN
OPERATION
Setting/Changing the Temperature
Example: Change the temperature setting from 300° to 450°C.
1. Press the
on temperature setting
section for more than one second.
●
The station goes into temperature setting
mode and the HUNDREDS digit flashes on
the display, indicating that the HUNDREDS
digit can be entered.
2. Enter the HUNDREDS digit.
●
Use the
UP
and
DOWN
buttons to select the
desired value for the HUNDREDS digit. Only
1, 2, 3, or 4 can be selected. (In °F mode,
2, 3, 4, 5, 6, 7, and 8 can be selected). When
the desired value is displayed, press the
button. The TENS digit begins to flash.
3. Enter TENS digit.
●
Use the
UP
and
DOWN
buttons to select the
desired value for the TENS digit. Any value
from 0 to 9 can be selected. When the
desired value is displayed, press the
button. The UNITS digit begins to flash.
4. Enter the UNITS digit.
●
Select the desired value for the UNITS digit
in the same manner as for the TENS digit.
●
Press the
button.
●
The temperature setting is stored in memory.
Heater control begins after the new
temperature setting is displayed.
CAUTION
If the power is turned OFF before the temperature
setting procedure is completed, the new setting value
will not be stored in memory.
CAUTION
The temperature setting range is 100° –
450°C. (212° – 842°F).
●
Attempt to enter a value outside the setting range will
cause the display to begin flashing the HUNDREDS
digit again. Reenter a correct value.
●
Both the display temperature and the temperature
setting are the temperature at the sensor. (Even with
the same temperature setting, the temperature of the
hot air differs depending on the nozzle size.)
11