7. PARTS LIST
●
Nothing happens when the power switch
is turned on.
●
Even if a remote control button is pressed,
the fume extractor does not operate.
●
Remote control channel cannot be set.
4. OPERATION
HAKKO FA-431 can be operated using the remote control.
●
Operation of the remote control
5. MAINTENANCE
Performing proper and periodic maintenance extends the product life. Wear of the product will differ
depending on work environment, the quality and quantity of the solder and flux.
Apply the following service procedure as dictated by the conditions of the usage.
●
Filter replacement timing
When replacing the filter, please be performed in a state in which the fan has stopped.
NOTE
:
ON
OFF
CH 1
CH 2
CH 3
CH 4
OFF button
ON button
Channel selection
buttons
The remote control has the following buttons:
●
ON button
Starts the fan of the HAKKO FA-431.
●
OFF button
Stops the fan of the HAKKO FA-431.
●
Channel selection buttons (CH1 to CH4)
・
Sets the channel of the remote control to the same channel as the HAKKO FA-431 main unit.
・
When one of the channel selection buttons (channels CH1 to CH4 are selectable) is held
pressed together with the OFF button for 2 seconds or longer, sets the channel of the remote
control itself to the pressed channel.
※When the channels of the remote control and the HAKKO FA-431 are the same, pressing the
remote control's ON button will cause the fume extractor to operate. (Both units are initially
set to channel CH1.)
Example : Setting to channel 3
1. Set the flow selection switch of the HAKKO FA-431
to CH SET.
2. While holding the OFF button of the remote control
pressed, press CH3 and hold both buttons pressed
for approximately 2 seconds.
3. When channel setting has been completed, the LED
on the main unit will blink twice and the buzzer will
sound the same number of times as the set channel.
Hold pressed for approx. 2 sec.
※When using multiple HAKKO FA-431 units, all fume extractors set to the same channel as
the remote control will operate when the remote control is used. Operation of fume extractors
according to the application can be performed by changing the channel setting of the fume
extractors as necessary.
If the remote control stops operating
completely, it might be because the
battery (CR2032) is completely exhausted.
Replace the battery.
CAUTION
If the above procedure is performed without setting the main unit's flow selection switch
to CH SET, only the channel of the remote control will be changed and operation by remote
control cannot be performed. If this occurs, perform the channel setting procedure again.
CAUTION
②
CR2032
①
●
How to set the channel
7. PARTS LIST
6. TROUBLE SHOOTING GUIDE
CHECK
:
ACTION :
CHECK
:
ACTION :
CHECK
:
ACTION :
CHECK
:
ACTION :
CHECK
:
ACTION :
CHECK
:
ACTION :
CHECK
:
ACTION :
CHECK
:
ACTION :
Is the power cord disconnected ?
Connect it.
Is the main filter set properly ?
Fit the main filter properly before turning
on the power switch again.
Is the flow control set to CH SET ?
Adjust the flow suitable for working environment
by using the flow selection switch.
Is the flow control set to CH SET ?
Adjust the flow suitable for working environment
by using the flow selection switch.
Are the remote control and HAKKO
FA-431 set to different channels?
Set both units to the same channel.
Is the battery of the remote control
exhausted?
Replace the battery.
Is the flow selection switch set to a
setting other than CH SET?
Set the flow selection switch to CH SET.
Is the battery of the remote control exhausted?
Replace the battery.
Instruction manual in the language of Japanese, English, Chinse, French, German and Korean
can be downloaded from the HAKKO Document Portal.
(Please note that some languages may not be available depending on the product.)
●
HAKKO FA-431
Pre-filter
Main filter
Cap
Knob
Power switch
Power cord, 3 wired cord but no plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord& European plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord & Australian plug
Power cord, 3 wired cord & Chinese plug
Power cord, 3 wired cord & American plug (B)
Power cord, 3 wired cord & SI plug
Power cord, 3 wired cord & BR plug
Power cord, 3 wired cord & American plug (U)
Remote control
1
2
3
4
5
6
7
A5034
A5033
B3619
B1486
B2852
B2421
B2422
B2424
B2425
B2426
B2436
B3508
B3550
B3616
B3641
C5035
Part No.
Part Name
Specifications
Item No.
10 pcs.
220 - 240V
India
220V KTL , 230V CE
230V CE , U.K.
China
U.S.A.
Specifications
1
2
10
5
7
4
3
6
3
4
9
9
8
11
●
Option
Duct set /
Rectangular nozzle
Duct set /
Round nozzle
Duct
Adapter
Adapter
Rectangular nozzle
Round nozzle
Bench top hood
Net
Duct
Duct band
Sub-filter
Sub filter / for rectangular nozzle
Sub filter / for round nozzle
Filter case / for rectangular nozzle
Filter case / for round nozzle
Duct (1) / Adapter (1)
Rectangular nozzle(1) / Net (1)
Duct (1) / Adapter (1)
Round nozzle (1) / Net (1)
φ 55 mm
For 3 inch
5 pcs.
For 3 inch (φ 75 mm)
Set of 2
5 pcs.
20 pcs.
20 pcs.
C1571
C1572
B3642
B3620
B3621
B3622
B3623
B2418
B3625
B2410
B2416
A5035
A5036
A5037
B5146
B5147
Item No. Part No.
Part Name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12
13
14
15
16
7