background image

7. PARTS LIST

 Nothing happens when the power switch 

is turned on.

 Even if a remote control button is pressed, 

the fume extractor does not operate.

 Remote control channel cannot be set.

4. OPERATION

HAKKO FA-431 can be operated using the remote control.

● 

Operation of the remote control

5. MAINTENANCE

Performing proper and periodic maintenance extends the product life. Wear of the product will differ 

depending on work environment, the quality and quantity of the solder and flux.  

Apply the following service procedure as dictated by the conditions of the usage.

● 

Filter replacement timing

When replacing the filter, please be performed in a state in which the fan has stopped.

NOTE

ON

OFF

CH 1

CH 2

CH 3

CH 4

OFF button

ON button

Channel selection 

buttons

The remote control has the following buttons:

 ON button

Starts the fan of the HAKKO FA-431.

 OFF button

Stops the fan of the HAKKO FA-431.

 Channel selection buttons (CH1 to CH4)

Sets the channel of the remote control to the same channel as the HAKKO FA-431 main unit.

When one of the channel selection buttons (channels CH1 to CH4 are selectable) is held 

pressed together with the OFF button for 2 seconds or longer, sets the channel of the remote 

control itself to the pressed channel.

※When the channels of the remote control and the HAKKO FA-431 are the same, pressing the 

remote control's ON button will cause the fume extractor to operate. (Both units are initially 

set to channel CH1.)

Example : Setting to channel 3

1. Set the flow selection switch of the HAKKO FA-431 

to CH SET.

2. While holding the OFF button of the remote control 

pressed, press CH3 and hold both buttons pressed 

for approximately 2 seconds.

3. When channel setting has been completed, the LED 

on the main unit will blink twice and the buzzer will 

sound the same number of times as the set channel.

Hold pressed for approx. 2 sec.

※When using multiple HAKKO FA-431 units, all fume extractors set to the same channel as 

the remote control will operate when the remote control is used. Operation of fume extractors 

according to the application can be performed by changing the channel setting of the fume 

extractors as necessary.

If the remote control stops operating 

completely, it might be because the 

battery (CR2032) is completely exhausted. 

Replace the battery.

CAUTION

If the above procedure is performed without setting the main unit's flow selection switch 

to CH SET, only the channel of the remote control will be changed and operation by remote 

control cannot be performed. If this occurs, perform the channel setting procedure again.

CAUTION

CR2032

 How to set the channel

7. PARTS LIST

6. TROUBLE SHOOTING GUIDE

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

CHECK

 : 

ACTION : 

Is the power cord disconnected ?

Connect it.

Is the main filter set properly ?

Fit the main filter properly before turning 

on the power switch again.

Is the flow control set to CH SET ?

Adjust the flow suitable for working environment 

by using the flow selection switch.

Is the flow control set to CH SET ?

Adjust the flow suitable for working environment 

by using the flow selection switch.

Are the remote control and HAKKO 

FA-431 set to different channels?

Set both units to the same channel.

Is the battery of the remote control 

exhausted?

Replace the battery.

Is the flow selection switch set to a 

setting other than CH SET?

Set the flow selection switch to CH SET.

Is the battery of the remote control exhausted?

Replace the battery.

Instruction manual in the language of Japanese, English, Chinse, French, German and Korean

can be downloaded from the HAKKO Document Portal.

(Please note that some languages may not be available depending on the product.) 

HAKKO FA-431

Pre-filter

Main filter

Cap

Knob

Power switch 

Power cord, 3 wired cord but no plug

Power cord, 3 wired cord & BS plug

Power cord, 3 wired cord& European plug

Power cord, 3 wired cord & BS plug

Power cord, 3 wired cord & Australian plug

Power cord, 3 wired cord & Chinese plug

Power cord, 3 wired cord & American plug (B)

Power cord, 3 wired cord & SI plug

Power cord, 3 wired cord & BR plug

Power cord, 3 wired cord & American plug (U)

Remote control

1

2

3

4

5

6

7

A5034

A5033

B3619

B1486

B2852

B2421

B2422

B2424

B2425

B2426

B2436

B3508

B3550

B3616

B3641

C5035

Part No.

Part Name      

Specifications

Item No.

10 pcs.

220 - 240V

India

220V KTL , 230V CE

230V CE , U.K.

China

U.S.A.

Specifications

1

2

10

5

7

4

3

6

3

4

9

9

8

11

Option

Duct set / 

Rectangular nozzle

Duct set / 

Round nozzle

Duct

Adapter

Adapter

Rectangular nozzle 

Round nozzle 

Bench top hood 

Net

Duct

Duct band 

Sub-filter

Sub filter / for rectangular nozzle

Sub filter / for round nozzle

Filter case / for rectangular nozzle

Filter case / for round nozzle

Duct (1) / Adapter (1)

Rectangular nozzle(1) / Net (1)

Duct (1) / Adapter (1)

Round nozzle (1) / Net (1)

φ 55 mm

For 3 inch

5 pcs.

For 3 inch (φ 75 mm)

Set of 2

5 pcs.

20 pcs.

20 pcs.

C1571

C1572

B3642

B3620

B3621

B3622

B3623

B2418

B3625

B2410

B2416

A5035

A5036

A5037

B5146

B5147

Item No. Part No.

Part Name      

1

2

3
4
5
6
7
8
9

10
11
12
13
14
15
16

12

13

14

15

16

7

Reviews: