2
Filter pipe assembly
Replace as a cartridge.
Front holder
Back holder
Back holder release button
The back holder will be locked
until this button is presssed.
Nozzle release button
Remove the nozzle from
the grip while pressing this button.
Nozzle
(Not included)
Back holder bushing
Push button
Suction start switch (when straight grip is used).
Trigger
Suction start switch (when
gun style handle is used).
Slide button
To remove the gun handle,
slide the button up to unlock it.
2. SPECIFICATIONS
●
HAKKO FM-205 desoldering station
Power Consumption 80 W
Temperature Range
200 to 450ºC (400 to 840ºF)
Temperature Stability ±5°C (±9°F) at idle temperature
●
Station
Output
24 V
Dimensions (W x H x D) 160 × 120 × 225 mm (6.3 × 4.7 × 8.9 in)
Weight
3.4 kg (7.5 lbs.)
Vacuum Generator
Ejector type
Vacuum Pressure (Max.) 93kPa (28 in. Hg)
Suction Flow
20 L/min.*
Applied Air Pressure
490 kPa (71 psi) When in use (trigger
or button is pressed)
Compressed Air Consumption 46 L/min.
* This suction flow is measured at the filter case suction port of
Station.
●
HAKKO FM-2027 (Option)
Power Consumption 70 W (24 V)
Tip to Ground Resistance < 2
Ω
Tip to Ground Potential < 2 mV
Total Length (w/o cord) 188 mm (7.4 in.) with 2.4D tip
Weight (w/o cord)
30 g (0.067 lb./1.07 oz.)with 2.4D tip
Cord
1.2 m (4 ft)
●
MODEL FM-2024 desoldering tool
Power consumption 70 W (24 V)
Temperature range 350 - 450°C (650 - 840°F)
Tip to ground potential < 2 mV
Tip to ground resistance < 2
Ω
Length, less cord
180 mm (7.0 in.)
Weight, less cord & hose 65 g (2.3 oz.)
Length of cord
1.2 m (4 ft.)
* The temperatures were measured using the HAKKO FG-
101 soldering tester.
* This product is protected against electrostatic discharge.
●
MODEL FM-2024 desoldering tool
CAUTION
This product includes such features as electrically conductive plastic parts and grounding of the handpiece and station as
measures to protect the device to be soldered from the effects of static electricity. Be sure to observe the following instructions:
1. The handle and other plastic parts are not insulators, they are conductors. When replacing parts or repairing, take sufficient
care not to expose live electrical parts or damage insulation materials.
2. Be sure to ground the unit during use.
* Specifications and design are subject to change without notice.
電路板
吸錫槍部分
插頭
插座
焊鐵座