4
A. Iron holder
●
Operation
First, remove any excess solder from the tip by
thrusting the tip into the cleaning wire. (Do not
wipe the tip against the wire. This may cause
molten solder to spatter.)
1. Insert the holder assembly securely into the
Iron holder base.
2. When the wire becomes dirty or loaded with
solder, turn the wire until a clean surface is
presented.
3. When changing the cleaning wire, lift the case
top vertically to prevent solder debris from
falling out.
4. Place the spare tips in the tip tray.
●
Use of the sleep function
When using the sleep function, insert one end of
the connecting cable into the jack at the back of
the iron holder and the other end into the jack at
the back of the desoldering station to connect
them.
CAUTION
• Be sure to turn off the power before connecting or
disconnecting the connecting cable.
• Securely insert the plug all the way into the jack.
B. MODEL FM-2024
●
Connecting and replacing the filter pipe
Pull the back holder until it locks, then
insert the filter pipe assembly with the opening
to the nozzle side. Ensure that the outer
surface of the filter pipe assembly is even with
the handle support. If the filter pipe assembly
is tilted, a leak may occur.
To replace the filter pipe assembly, press back
holder release button , pull the back holder
to lock it, change the filter pipe assembly, then
lock the filter pipe assembly. Replace the filter
pipe assembly in the cartridge.
4. INITIAL SETUP
Jack to connecting cable
Connecting cable
CAUTION
The surface of the filter pipe
assembly may be very hot.