 Initial Reset

With initial reset, you can return the settings (except for the password) to what they were when it was 

shipped from the factory. The selection and execution methods are the same as the methods for the other 

settings.

Initial Reset

OK

Cancel

 Explanations of each channel parameter and setting method

For the channel parameters, the displayed screen will differ depending on which handpiece is attached the applicable channel. 

Auto Sleep

Sleep Temp

Low Temp

Error Alarm

Ready Alarm

Exit

CH1

Error Alarm

Ready Alarm

Pump Select

Exit

CH3

All handpieces EXCEPT FM-2029

FM-2029 Handpiece ONLY

06m

200

150

ON

ON

ON

ON

Int

The reason the display screen is different is because the necessary setting items differ according to the 

connected handpiece. Below, the setting method for each item is illustrated.

 Auto Sleep

Select whether you want to activate the soldering iron's sleep function. When activated, the sleep 

function will turn on when then handpiece has been placed in the sleep holder for a set period of time 

and the temperature of the iron tip will drop* to a set temperature.

Error Alarm

Ready Alarm

Exit

ON

ON

CH1

No Handpiece Connected

ON

Off

Auto Sleep

Setting

06min

Select 

"Off"

Auto Sleep

Sleep Temp

Low Temp

Error Alarm

Ready Alarm

Exit

CH1

Off

200

150

ON

ON

ON

Off

Auto Sleep

Setting

0

6min

Select "On"

When changing your selection or changing 

the numerical value, turn the control knob 

and press the control knob when you have 

made your choice.

After the last digit has been accepted for 

the time setting, the screen will return to the 

previous screen as if the setting were OFF.

 Sleep Temperature

This sets the temperature when it is sleeping. The setting for the sleep temperature is not entered one digit 

at a time, the displayed temperature changes in 20 

℃ 

(36

) increments by turning the operating knob. 

When the desired temperature is displayed, you can set it by pressing the operating knob.

* The temperature when it is lowered is set as "Sleep Temp".

Sleep

Temperature

200℃

 Low Temp Alert Setting

Set the lower-limit error temperature. When this function is activated, if the sensor temperature goes below 

the lower-limit temperature, an error will be displayed and the warning buzzer will sound. Change the value 

by turning the control knob, and pressing the control knob to accept the value.

Low  Temp Alert

Setting

1

50℃

P a r a m e t e r

C H 1

C H 2

C H 3

E x i t

When the channel parameter is selected, the screen 

shown to the right will be displayed. When you select 

the channel you want to set here, it will switch to that 

channel's setting screen.
Turn the control knob when you want to change the 

selection, and press the control knob when you have 

made your choice.

NOTE

The password lock function and the password 

will be maintained even after an initial reset. 

Select

Accept

Select

Execute

Select

Accept

Change 

value

Accept

Change numerical 

value

Execute

6. PARAMETER SETTINGS

11

Summary of Contents for fm-206

Page 1: ...2027 200 450 400 840 MODEL FM 2022 2023 200 400 400 750 MODEL FM 2024 350 450 660 840 HAKKO FM 2029 100 550 200 1030 HAKKO FM 2030 2031 200 500 400 930 5 C 9 F at idle temperature 24V 162 136 245 mm 6...

Page 2: ...use or left unattended Turn the power off when connecting the handpieces or storing the HAKKO FM 206 This appliance is not intended for use by persons including children with reduced physical sensory...

Page 3: ...ece with the exception of the HAKKO FM 2027 has their own instruction manual Please refer to this manual for specifications and replacement parts Switch Control Button and Knob Usage Power switch Use...

Page 4: ...the channel is in operation and it will return to the screen before the preset selection screen if the channel is not in operation Set Temp Offset Temp Preset Temp Preset ID CH Power Initial Value 350...

Page 5: ...is an example using the SETTING TEMPERATURE display 350 Setting Temperature 450 Setting Temperature 450 Setting Temperature 450 Setting Temperature 4 After the last digit has been accepted by pressing...

Page 6: ...Preset1 ID QRESET1 Preset1 ID PRESET1 Preset1 ID PRESET1 Preset1 ID 4 Once you accept the value for the last character the menu returns to the PRESENT ID list PRESET4 Preset1 ID PRESET4 PRESET2 PRESET...

Page 7: ...ss the control knob when you have made your choice HotAir Mode Offset Temp Timer Mode Time Unit Profile Ch Power Exit Auto 00 Opn m s ON CH3 Auto mode Timer Mode for Auto Mode Opened Closed On the dif...

Page 8: ...control knob it will switch to the profile setting screen Exit 400 0m30s 350 0m30s 300 0m30s Exit 400 0m30s 350 0m30s 300 0m30s 2 When you press the control knob once in the profile setting screen you...

Page 9: ...e Temp Mode Auto Shut Off Vaccum Mode Vacuum Time Password Lock Password Initial Reset Initial value Off Normal 1sec OFF none System parameters Value Off 30min 60min Normal Timer 1 5sec ON Partial OFF...

Page 10: ...ntered Check your password once more and then enter it Input Password AA Input Password A Enter the last character Input failure Successfully entered Return to the screen where you enter the current p...

Page 11: ...lection or changing the numerical value turn the control knob and press the control knob when you have made your choice After the last digit has been accepted for the time setting the screen will retu...

Page 12: ...sound or not when the iron tip etc has reached the set temperature and is ready for use Turn the control knob and select ON or OFF and press the control knob to accept ON Off Ready Alarm Setting Pump...

Page 13: ...FM 206 ensure effective soldering at low temperatures Always clean the tip nozzle before use to remove any residual solder or flux adhering to it Use the tip cleaner or cleaning sponge Contaminants o...

Page 14: ...e pump head 1 Remove the valve and valve guard and remove any attached flux Caution When the valve guard is difficult to remove please warm it with hot air Please do not try to forcibly remove it with...

Page 15: ...ron desoldering tool or handpiece CHECK Is the tip temperature too high ACTION Set the appropriate temperature CHECK Is the tip contaminated with oxide ACTION Remove the oxide CHECK Is the connection...

Page 16: ...L FM 2023 are connected This is displayed in cases such as when judged that an excessive pulse has been generated when the micro tweezers MODEL FM 2023 are connected A trig error will occur if the tri...

Page 17: ......

Page 18: ...ith O ring Item No 1 2 3 4 5 6 7 8 9 10 HAKKO FM 206 Specifications Transformer Temp Control display 6MM 100L 6MM 115L 6MM 220L 3MM 170L Part No A1583 A1584 B3667 B3668 B3669 B3670 B3671 B3672 B3673 B...

Page 19: ...5 6 7 8 Part No B3001 B2791 B3248 B3251 B3249 B3250 B3252 599B 02 599 029 Part Name Iron receptacle Tip fixing spring Holder for iron receptacle Iron holder base Cleaner base Stay Switch case assembl...

Reviews: