Initial Reset
With initial reset, you can return the settings (except for the password) to what they were when it was
shipped from the factory. The selection and execution methods are the same as the methods for the other
settings.
Initial Reset
OK
Cancel
■
Explanations of each channel parameter and setting method
For the channel parameters, the displayed screen will differ depending on which handpiece is attached the applicable channel.
Auto Sleep
Sleep Temp
Low Temp
Error Alarm
Ready Alarm
Exit
CH1
Error Alarm
Ready Alarm
Pump Select
Exit
CH3
All handpieces EXCEPT FM-2029
FM-2029 Handpiece ONLY
06m
200
℃
150
℃
ON
ON
ON
ON
Int
The reason the display screen is different is because the necessary setting items differ according to the
connected handpiece. Below, the setting method for each item is illustrated.
●
Auto Sleep
Select whether you want to activate the soldering iron's sleep function. When activated, the sleep
function will turn on when then handpiece has been placed in the sleep holder for a set period of time
and the temperature of the iron tip will drop* to a set temperature.
Error Alarm
Ready Alarm
Exit
ON
ON
CH1
No Handpiece Connected
ON
Off
Auto Sleep
Setting
06min
Select
"Off"
Auto Sleep
Sleep Temp
Low Temp
Error Alarm
Ready Alarm
Exit
CH1
Off
200
℃
150
℃
ON
ON
ON
Off
Auto Sleep
Setting
0
6min
Select "On"
When changing your selection or changing
the numerical value, turn the control knob
and press the control knob when you have
made your choice.
After the last digit has been accepted for
the time setting, the screen will return to the
previous screen as if the setting were OFF.
●
Sleep Temperature
This sets the temperature when it is sleeping. The setting for the sleep temperature is not entered one digit
at a time, the displayed temperature changes in 20
℃
(36
℉
) increments by turning the operating knob.
When the desired temperature is displayed, you can set it by pressing the operating knob.
* The temperature when it is lowered is set as "Sleep Temp".
Sleep
Temperature
200℃
●
Low Temp Alert Setting
Set the lower-limit error temperature. When this function is activated, if the sensor temperature goes below
the lower-limit temperature, an error will be displayed and the warning buzzer will sound. Change the value
by turning the control knob, and pressing the control knob to accept the value.
Low Temp Alert
Setting
1
50℃
P a r a m e t e r
C H 1
C H 2
C H 3
E x i t
When the channel parameter is selected, the screen
shown to the right will be displayed. When you select
the channel you want to set here, it will switch to that
channel's setting screen.
Turn the control knob when you want to change the
selection, and press the control knob when you have
made your choice.
NOTE
:
The password lock function and the password
will be maintained even after an initial reset.
Select
Accept
Select
Execute
Select
Accept
Change
value
Accept
Change numerical
value
Execute
6. PARAMETER SETTINGS