background image

5. OPERATION

 Various setting changes (Preset select)

 Range of preset temperatures

Grip
HAKKO FM-2027 / FM-2026
MODEL FM-2022 / FM-2023
MODEL FM-2024
HAKKO FM-2030 / FM-2031
HAKKO FM-2029

Initial Value
300/350/400

 (570/660/750

)

300/350/400

 (570/660/750

)

350/375/400

 (660/700/750

)

300/350/400

 (570/660/750

)

300/350/400

 (570/660/750

)

Initial preset temperatures for each grip

* When the acceptable setting range is exceeded it will 

return to the initial setting. 

(For the setting range, refer to "Initial preset temperatures 

 for each grip.")

**The setting temperature, offset temperature, preset 

temperature, and preset name are remembered by 

each grip.

1. Press the control button for the channel you want to change.

The display screen will switch to the preset selection screen shown below.

Set Temp 350

PRESET1

PRESET2

PRESET3

300

350

400

E x i t

C H 1

P r e s e t S e l e c t

CH1

   

CH2

   

CH3

350

℃   

Off

   

Off

SOL

2. By turning the control knob, the preset temperature to be selected will change.

Set Temp 350

PRESET1

PRESET2

PRESET3

300

350

400

E x i t

C H 1

P r e s e t S e l e c t

Set Temp 350

PRESET1

PRESET2

PRESET3

300

350

400

E x i t

C H 1

P r e s e t S e l e c t

3. Press the control knob when the desired preset temperature is highlighted.

The iron tip will now be set to the selected preset temperature.

Set Temp 350

PRESET1

PRESET2

PRESET3

300

350

400

E x i t

C H 1

P r e s e t S e l e c t

CH1

   

CH2

   

CH3

400

℃  

Off

   

Off

SOL

* Should you press another control button while in the preset selection screen, it will shift to that channel's 

preset selection screen if the channel is in operation, and it will return to the screen before the preset 

selection screen if the channel is not in operation.

Set Temp
Offset Temp
Preset Temp
Preset ID
CH Power

Initial Value
350

 (750

)

0

 (0

)

(Varies by grip)
PRESET1 / PRESET2 / PRESET3
ON

Items that can be changed during normal operation and initial setting

Possible Change Range
Refer to "Temperature ranges for each grip."
+/- 50

 

(+/- 90

)

Refer to "Temperature ranges for each grip."
Input up to 7 characters (English nu '_').
ON / OFF

*For setting items pertaining to the HAKKO FM-2029 Hot Air Pencil, please refer to "Settings for the 

HAKKO FM-2029 Hot Air Pencil" later in this manual.

Grip
HAKKO FM-2027 / FM-2026
MODEL FM-2022 / FM-2023
HAKKO FM-2024
HAKKO FM-2030 / FM-2031
HAKKO FM-2029

Setting Temperature Range
200

450

 

400

840

200

400

 

400

750

350

450

 

660

840

200

500

 

400

930

100

550

 

200

1030

Temperature range for each grip

1. Press and hold the control button for the channel you want to change for approximately 1 second. 

The display screen will switch to the setting selection screen shown below.

Set  Temp

Offset 

 

Temp

Preset  Temp

Preset  ID

Ch  Power

Exit

350

00

ON

CH1

CH1

   

CH2

   

CH3

350

℃  

Off

   

Off

SOL

2. Select the item you want to change in the screen above by turning the control knob to highlight the item, 

and press the control knob to change the setting. When you are finished, turn the control knob to select 

EXIT and press the control knob.

CH1

   

CH2

   

CH3

350

℃  

Off

   

Off

SOL

Set  Temp

Offset 

 

Temp

Preset  Temp

Preset  ID

Ch  Power

Exit

350

00

ON

CH1

 Selecting the Preset Temperature

 Changing various settings (other than preset selections)

 Setting items, possible change range and initial value

 Change procedures (initial and when finished)

4

Summary of Contents for fm-206

Page 1: ...2027 200 450 400 840 MODEL FM 2022 2023 200 400 400 750 MODEL FM 2024 350 450 660 840 HAKKO FM 2029 100 550 200 1030 HAKKO FM 2030 2031 200 500 400 930 5 C 9 F at idle temperature 24V 162 136 245 mm 6...

Page 2: ...use or left unattended Turn the power off when connecting the handpieces or storing the HAKKO FM 206 This appliance is not intended for use by persons including children with reduced physical sensory...

Page 3: ...ece with the exception of the HAKKO FM 2027 has their own instruction manual Please refer to this manual for specifications and replacement parts Switch Control Button and Knob Usage Power switch Use...

Page 4: ...the channel is in operation and it will return to the screen before the preset selection screen if the channel is not in operation Set Temp Offset Temp Preset Temp Preset ID CH Power Initial Value 350...

Page 5: ...is an example using the SETTING TEMPERATURE display 350 Setting Temperature 450 Setting Temperature 450 Setting Temperature 450 Setting Temperature 4 After the last digit has been accepted by pressing...

Page 6: ...Preset1 ID QRESET1 Preset1 ID PRESET1 Preset1 ID PRESET1 Preset1 ID 4 Once you accept the value for the last character the menu returns to the PRESENT ID list PRESET4 Preset1 ID PRESET4 PRESET2 PRESET...

Page 7: ...ss the control knob when you have made your choice HotAir Mode Offset Temp Timer Mode Time Unit Profile Ch Power Exit Auto 00 Opn m s ON CH3 Auto mode Timer Mode for Auto Mode Opened Closed On the dif...

Page 8: ...control knob it will switch to the profile setting screen Exit 400 0m30s 350 0m30s 300 0m30s Exit 400 0m30s 350 0m30s 300 0m30s 2 When you press the control knob once in the profile setting screen you...

Page 9: ...e Temp Mode Auto Shut Off Vaccum Mode Vacuum Time Password Lock Password Initial Reset Initial value Off Normal 1sec OFF none System parameters Value Off 30min 60min Normal Timer 1 5sec ON Partial OFF...

Page 10: ...ntered Check your password once more and then enter it Input Password AA Input Password A Enter the last character Input failure Successfully entered Return to the screen where you enter the current p...

Page 11: ...lection or changing the numerical value turn the control knob and press the control knob when you have made your choice After the last digit has been accepted for the time setting the screen will retu...

Page 12: ...sound or not when the iron tip etc has reached the set temperature and is ready for use Turn the control knob and select ON or OFF and press the control knob to accept ON Off Ready Alarm Setting Pump...

Page 13: ...FM 206 ensure effective soldering at low temperatures Always clean the tip nozzle before use to remove any residual solder or flux adhering to it Use the tip cleaner or cleaning sponge Contaminants o...

Page 14: ...e pump head 1 Remove the valve and valve guard and remove any attached flux Caution When the valve guard is difficult to remove please warm it with hot air Please do not try to forcibly remove it with...

Page 15: ...ron desoldering tool or handpiece CHECK Is the tip temperature too high ACTION Set the appropriate temperature CHECK Is the tip contaminated with oxide ACTION Remove the oxide CHECK Is the connection...

Page 16: ...L FM 2023 are connected This is displayed in cases such as when judged that an excessive pulse has been generated when the micro tweezers MODEL FM 2023 are connected A trig error will occur if the tri...

Page 17: ......

Page 18: ...ith O ring Item No 1 2 3 4 5 6 7 8 9 10 HAKKO FM 206 Specifications Transformer Temp Control display 6MM 100L 6MM 115L 6MM 220L 3MM 170L Part No A1583 A1584 B3667 B3668 B3669 B3670 B3671 B3672 B3673 B...

Page 19: ...5 6 7 8 Part No B3001 B2791 B3248 B3251 B3249 B3250 B3252 599B 02 599 029 Part Name Iron receptacle Tip fixing spring Holder for iron receptacle Iron holder base Cleaner base Stay Switch case assembl...

Reviews:

Related manuals for fm-206