5. OPERATION
●
Settings for the HAKKO FM-2029 Hot Air Pencil
The Hot Air Pencil can only be used on CH3. When you connect it, the screen will be as shown below.
CH1
CH2
CH3
350
℃
Off
Ready
SOL
100%
M
When on standby
CH1
CH2
CH3
350
℃
Off
120
℃
SOL
100%
M
When in use
The Hot Air Pencil has a manual mode and an auto mode, and the settings that can be changed are different.
HotAir Mode
Set Temp
Offset Temp
Preset Temp
Preset ID
Ch Power
Exit
Man
350
℃
00
℃
ON
CH3
Manual mode
HotAir Mode
Offset Temp
Timer Mode
Time Unit
Profile
Ch Power
Exit
Auto
00
℃
Opn
m-s
ON
CH3
In either case, the screen is set to scroll since all of the items cannot fit on the screen. In manual mode, other
than selecting Hot Air Mode, both the changing method and initial settings are the same as the other grips.
●
Initial settings when in auto mode
The steps for changing settings with the same name are the same as the setting method for the other grips.
The steps for changing settings not previously covered are illustrated below.
●
Changing Timer Mode
1. Turn the control knob, select "Timer Mode," and press the control knob when you have made your
choice.
HotAir Mode
Offset Temp
Timer Mode
Time Unit
Profile
Ch Power
Exit
Auto
00
℃
Opn
m-s
ON
CH3
Auto mode
Timer Mode
for Auto-Mode
Opened
Closed
■
On the difference between Opened and Closed in "Timer Mode"
In Auto mode, the temperature profile shown below is followed by the system. In OPENED timer mode, the
time for each step starts the countdown once the output air temperature reaches the set value. In CLOSED
timer mode, the timer starts immediately regardless if the output air temperature has reached the set value
or not.
Step 1
Step 2
Step 3
Closed
Opened
Time
Air temperature
Temperature
rising
Temperature
stable
Temperature
rising
Temperature
stable
Temperature
rising
Temperature
stable
Temperature falling*
*In Auto mode, a 15 second cool-down will be performed after all steps are completed and the air will stop.
2.When you have selected the desired setting, press the control knob.
HotAir Mode
Offset Temp
Timer Mode
Time Unit
Profile
Ch Power
Exit
Auto
00
℃
Opn
m-s
ON
CH3
Timer Mode
for Auto-Mode
Opened
Closed
Offset Temp
Timer Mode
Time Unit
Profile
(Temp)
(Time)
Ch Power
Initial Value
0℃ (0℉)
Opened
min-sec
300/350/400℃ (570/660/750℉)
30/30/30sec
ON