Parameter name
AutoSleep
Sleep Temp
Low Temp
Error Alarm
Ready Alarm
Pump Select*
Exit
Initial value
6min
200℃ (390℉
)
150℃ (270℉
)
On
On
Internal
Channel parameters
Value
OFF / 0 ~ 29min
200 ~ 300℃ increments of 20℃
(390 ~ 570℉ increments of 36℉
)
30 ~ 150℃ (54 ~ 270°
F
)
On / Off
On / Off
Internal / External
Explanation of each parameter and how to change the settings
●
Temperature Mode
The displayed temperature can be switched between Centigrade and Fahrenheit. Turn the control knob
to switch it and press the control knob when you have made your choice.
Temperature Mode
℃
°F
Select
Execute
●
Auto-Shut Off Setting
Select whether you will activate the auto shut off function. You can select from three options: OFF, 30
minutes or 60 minutes. Turn the control knob when making your selection and press the control knob
when you have made your choice.
Auto-ShutOff
Setting
Off
30min 60min
■
Parameter settings
For parameters, there are two types: system parameters and channel parameters. System parameters are used
for the settings for the entire system, and channel parameters are used for the settings for each channel.
The
change parameters screen can be displayed by turning on the power while the control knob is pressed.
6. PARAMETER SETTINGS
P a r a m e t e r
S y s t e m
C h a n n e l
E x i t
Parameter name
Temp Mode
Auto-Shut Off
Vaccum Mode
Vacuum Time*
Password Lock
Password**
Initial Reset
Initial value
℃
Off
Normal
1sec
OFF
none
System parameters
Value
℃ / ℉
Off / 30min / 60min
Normal / Timer
1
〜
5sec
ON / Partial / OFF
3 upper case alphabetic characters
OK / Cancel
*
"Vacuum Time" is displayed when "Timer" is selected in Vacuum Mode.
** "Password" is displayed when "ON" or "Partial" is selected for the Password Lock.
S y s t e m
Te m p M o d e
S h u t O f f S e t
Va c u u m M o d e
Va c u u m T i m e *
P a s s w o r d L o c k
P a s s w o r d * *
I n i t i a l R e s e t
E x i t
℃
O f f
T i m e
1 s
O n
System setting screen
●
Vacuum Mode Setting
Suction with the desoldering iron is performed either manually or in timer form. For mode selection, turn the
control knob and press the control knob when you have made your choice.
Vacuum Mode
Setting
Normal
Timer
●
Vacuum Time
This item is displayed when selecting "Timer" in Vacuum Mode. After suction, you can set the amount of
time it will operate after you remove your hand from the trigger. When changing the numerical value, turn
the control knob; Press the control knob to accept your selected value.
Change numerical
value
Accept
Vacuum Time
Setting
1
sec
Normal
Timer
: suction only when the trigger is pulled
: suction performed for a designated time*
even after you remove your hand from
the trigger
* Time setting is set as "Vacuum Time".
* "Pump Select" is displayed when a hot air
handpiece is connected to channel 3.
Select
Execute
Select
Execute
9