27
Figure 42: Prism Left/Right Image Adjustment
Figure 40: Mirror adjustment
Return the head to its uppermost position and turn
on the LCD monitor. Move the optics train (7) to its
right-most position. Loosen the locking screw (5)
on the mirror bracket very slightly and, using the
three set screws (6), adjust the mirror so the nozzle
tip appears in the center of the video image. Adjust
the lens zoom control through its entire travel to
ensure the image remains centered on the screen.
Re-tighten the center screw.
Figure 41: Aligning the calibration tip with the plate
Adjust the head down and align the calibration tip
(2) with the blind hole in the calibration plate (3)
using the X and Y fine adjustments. Adjust the X
and Y axes so that the tip can be moved easily in and
out of the hole in the Z direction.