51
Figure 7 – Screen capture from system operating in Teach Mode. The graph shows that the part
thermocouple has passed the Preheat Target (PH: 140) and is approaching the Soak Target (SK: 175).
Note that the “Soak” indicator is highlighted bright yellow. This is the active step. The paler colored
steps have already been completed. The Current Stage Time counts up in Teach Mode and down in
Run Mode.