1
4
8
2
6
5
7
3
■
Checking the connection
cord for breakage
■
Checking the grounding
line
Checking the connection cord for breakage
1. Unplug the connection cord from the station.
2. Disassemble the heating element. {Please
refer to [Replacing the heating element
(heating core)]}
3. Measure the resistance values between the
connector and the lead wires at the socket as
follows:
Pin1
・・・・・・・・・・・・
Red (
Socket
)
①
Pin2
・・・・・・・・・・・・
Green (
Grounding line
)
⑤
*
Pin3
・・・・・・・・・・・・
Black (
Switch board)
②
Pin5
・・・・・・・・・・・・
Yellow (
Switch board
)
③
Pin6
・・・・・・・・・・・・
Purple (
Switch board
)
④
Pin8
・・・・・・・・・・・・
Brown (
Socket
)
①
If any value exceeds 0 Ω or is ∞, replace the
connection cord.
* For information on the plug 2, refer to “
■
Checking the grounding line”)
1. Measure the resistance value between Pin 2
and the nozzle.
2. If the value exceeds 2 Ω (at room tempera
-
ture), perform the nozzle maintenance. If the
value still does not decrease, check the
connection cord for breakage.
28
Black
Switch board
Grounding
line
Socket
Green
Brown
Red
Yellow
Purple
①
②
③
④
⑤