9
7. PARAMETER SETTING (Soldering iron)
Soldering iron has the following parameters.
*1 It is displayed only when "1:Preset mode" is selected in the setting mode.
*2 It is displayed only when "1:Custom" is selected in the password setting.
*3 It is displayed only when either "1:Custom" or "2:valid" is selected in the password setting.
*4
○
: Password not required × : Password required
Parameter No.
Initial value
Parameter name
℃ / ℉ selection
Low temperature error setting
Setting mode selection
The number of preset
*1
Password setting
Temperature setting mode
*2
Preset mode
*2
Adjust mode
*2
Password
*3
℃
150
℃
0
0
-
Value
℃ / ℉
30 to 150℃ (54 to 270℉)
0
:
The normal mode
/ 1
:
The preset mode
(
2
pcs.)
to
(
5
pcs.)
0
:
Open
/ 1
:
Partial
/ 2
:
Restricted
:○
*4
/
:
×
*4
:○
*4
/
:
×
*4
:○
*4
/
:
×
*4
Select three letters
●
: ℃ or ℉ temperature display seletion
The displayed temperature can be switched between Celsius and Fahrenheit.
●
: Low temperature error setting
If the sensor temperature goes below the low-limit temperature although heating element is on, an error
will be displayed.
●
: Setting mode selection
Temperature setting can be switched between the normal mode and the preset mode.
If selecting the preset mode, you will be asked for the number of preset you required.
Press the button to set the number.
●
: Password setting
Select “Open”, “Partial” or “Restricted” for password setting.If selecting the Restricted, perform the
setting for password. If selecting the partial, choose whether or not the password function is needed
when moving to the temperature setting mode, the preset mode and the adjust mode and set the
password.
10
A. ℃ or ℉ temperature display selection
1. Either or will be displayed if you press the button when is displayed.
2. and will be switched alternately If you press the button.
3. The display will return to if you press the button after selecting.
B. Low temperature error setting
1. Press the button to change the display to .
2. The low-limit temperature will be displayed if you press the button. Enter the value in the same
manner as described in the normal mode 6. OPERATION (Soldering iron) “A. The temperature setting
mode”.
3. The display will return to if you press the button after setting.
C. Setting mode selection
1. Press the button to change the display to .
2. If you press the button, the display will move to the setting mode selection screen. If you press
the button, (The normal mode) and (The preset mode) will be switched alternately.
3. The display will return to if you press the button after selecting.*
* If you select the preset mode, the display will move to the preset selection screen.
4. The number of active preset will be displayed If you press the button at 3.
(Example : If the number is three, is displayed.)
5. Press the button to change the value and select the number of active preset you required.
The unit will accept values from 2 through 5.
6. The display will return to if you press the button after selecting.
●
Parameter setting mode
1. Turn off the power switch.
2. Turn on the power switch while pressing the button.
3. When the display shows , the station is in parameter setting mode.