11
D. Password setting
1. Press the button to change the display to .
2. If you press the button, the display will move to the setting mode selection screen.
If you press the button, (Open), (Partial) and (Restricted) will be switched
alternately.
3. If you press the button after selecting, the display will return to . *1, 2
*1 The display will move to the following selection screen if you select (Partial).
4. If you press the button at 3, you will be asked whether or not the password function is needed when
moving to the temperature setting mode.
5. Either (without password) or (with password) will be displayed if you press the button.
6. If you press the button after selecting, you will be asked whether or not the password function is needed
when moving to the preset selection mode.
7. Either (without password) or (with password) will be displayed if you press the button.
8. If you press the button after selecting, you will be asked whether or not the password function is needed
when moving to the adjust mode.
9. Either (without password) or (with password) will be displayed if you press the button.
10. If you press the button after selecting, the display will move to password setting screen.
*2
If you select (Restricted), the display will move to the following password setting screen. If you
select (Partial), the display will move to the following the password setting screen after selecting *1.
11. When the third digit is flashing, you can input the character you require. Press the button to change
the value of the third digit.
12. After determining the desired character ( ), press the button. The second digit will begin
to flash. Using the same procedure, enter the character you require for the second digit, and the first digit.
13. The display will return to if you press the button after entering the units digit.
After changing parameters, press and hold the button down for at least two seconds until is displayed.
At this time, you can switch between and by pressing the button. Select if you are
finished making changes or if you need to go back and make more changes. Press the button to
confirm you selection.
Changes will not be completed until is displayed and you press the button.
Please note that no changes will be made if you turn off the power while making changes.
7. PARAMETER SETTING (Soldering iron) (continued)
12
8. MAINTENANCE (Soldering iron)
Performing proper and periodic maintenance extends product life. Efficient soldering depends upon
the temperature, the solder / flux.
Apply the following service procedure as dictated by the conditions of usage.
●
Tip Maintenance
1. Set the temperature to 250℃ (482℉).
2. When the temperature stabilizes, clean the tip with the cleaning sponge and check the condition of the tip.
3. If the solder plated part of the tip is covered with black oxide, apply fresh solder containing flux, and
clean the tip again. Repeat until all the oxide is removed, then coat the tip with fresh solder.
4. If the tip is deformed or heavily eroded, replace it with a new one.
Since the soldering iron can reach a very high temperature, please work carefully. Except the case
especially indicated, always turn the power switch OFF and disconnect the power plug before performing
any maintenance procedure.
WARNING
CAUTION
Do not file the tip in an attempt to remove the black oxide.
■
Cleaning the tip using the iron holder
1. Using the cleaning sponge
2. Using the cleaning wire
Use the cleaning sponge that comes with the
product to clean the tip. It offers wide-ranging
uses, from simple removal of excess solder to
complete elimination of matter occurring as a
result of oxidization.
Material that is not removed easily with the
cleaning sponge can likely be removed using
the cleaning wire.