21
●
Set Temp (Nozzle temperature setting)
1. Move the cursor to select “Set Temp”. After selecting, press <ENT>.
2. Entering from hundreds to units digit
Press the <
↑
> or <
↓
> to set the desired figure.
Press the <ENT> button to advance to the next digit.
Only values from 3 to 4 can be selected when entering the hundreds digit.
(In ℉ mode, values from 6 to 8 can be selected.)
Values from 0 to 9 can be selected when entering the tens or units digits.
(The same values can be selected in ℉ mode.)
3. When desired figure is displayed, press the button to enter.
The next digit will begin to flash. After entering the units digit, press the button to
save the figure to the system memory and begin heater control with new setting
temperature.
CAUTION
The temperature range is from 330 to 450℃. ( 620 to 850℉)
If you enter a value outside the temperature setting range, the display returns to
the hundreds digit, and you have to enter a correct value.
CAUTION
If power is switched off or lost during the execution of this procedure, no data
will be entered. The entire procedure must be repeated from step 1.
<↑>
<↓>
<ENT>
S e t T e m p
O f f s e t T e m p
V a c u u m C h e c k
380゚ C
00゚ C
C
<↑>
<↓>
<ENT>
C
<↑>
<↓>
<ENT>
C
<↑>
<↓>
<ENT>
13. OPERATION (Desoldering Tool) (continued)
22
●
Offset Temp (Nozzle temperature offset setting)
1. Move the cursor to select “OffsetTemp”. After selecting, press <ENT>.
2. Enter the offset value (-05) which is the difference between tip temperature and set
temperature.
Press the <
↑
> or <
↓
> to set the desired figure.
Press the <ENT> button to advance to the next digit.
The hundreds digit can display 0 (for positive value) or minus sign. (for negative value)
(Same values can be selected in ℉ mode.)
Values from 0 to 5 can be selected when entering the ten digit.
(In ℉ mode, values from 0 to 9 can be selected.)
Values from 0 to 9 can be selected when entering the units digit.
(Same values can be selected in ℉ mode.)
3. After entering the units digit, press the button to save the figure to the system
memory and begin heater control with the new offset value.
CAUTION
During the offset setting, please be careful tip temperature does not exceed 450℃.
<↑>
<↓>
<ENT>
S e t T e m p
O f f s e t T e m p
V a c u u m C h e c k
380゚ C
00゚ C
C
<↑>
<↓>
<ENT>
C
<↑>
<↓>
<ENT>
C
<↑>
<↓>
<ENT>
Example
:
If the measured temperature is 405℃ and set temperature is 400℃, the
difference is -5℃. (need to decrease by 5℃) So, enter the figure which 5
is deducted from present offset value.
CAUTION
The allowable ranges for offset values are from -50 to +50℃ . (In ℉ mode, from -90
to +90℉) If you enter a value outside the offset value range, the display returns to
the hundreds digit, and you have to enter a correct value.