31
●
Sleep Temp
●
Low Temp
1. Move the cursor to select “SleepTemp”.
After selecting, press <ENT>.
Set the auto sleep temperature.
When the temperature drops below a set limit, an error is displayed and the buzzer
sounds.
2. Entering from hundreds to units digit.
Press the <
↑
> or <
↓
> to set the desired
figure.
Press the <ENT> button to advance to the next digit.
Only values from 2 to 3 can be selected when
entering the hundreds digit.
(In ℉ mode, values from 3 to 5 can be
selected.)
Values from 0 to 9 can be selected when
entering the tens or units digits.
(The same values can be selected in ℉ mode.)
2. Entering from hundreds to units digit.
Press the <
↑
> or <
↓
> to set the desired figure.
Press the <ENT> button to advance to the next digit.
Only values from 0 to 1 can be selected when
entering the hundreds digit.
(In ℉ mode, values from 0 to 2 can be
selected.)
Values from 0 to 9 can be selected when
entering the tens or units digits.
(The same values can be selected in ℉ mode.)
3. After entering the units digit, press the button
to save the figure to the system memory.
1. Move the cursor to select “Low Temp”.
After selecting, press <ENT>.
3. After entering the units digit, press the button
to save the figure to the system memory.
<↑>
<↓>
<ENT>
V a c u umM o d e
A u t o S l e e p
S l e e p T e m p
NOR
06
m
200゚ C
<↑>
<↓>
<ENT>
S l e e p T e m p S e t
00゚ C
<↑>
<↓>
<ENT>
A u t o S l e e p
S l e e p T e m p
L o w Te m p
06
m
200゚ C
150゚ C
<↑>
<↓>
<ENT>
L o w T e m p S e t
50゚ C
14. PARAMETER SETTING (Desoldering Tool) (continued)
32
●
Error Alarm
●
Ready Alarm
In the buzzer sound setting mode, which sets whether to sound the buzzer when a
error occurs.
When the set temperature alert setting mode is on, the buzzer sounds if you reached
the usable temperature.
1. Move the cursor to select “Error Alarm”.
After selecting, press <ENT>.
2. ON and OFF will be switched alternately
if you press the <
↑
> or <
↓
> button.
3. Return to parameter setting display if you
press the <ENT> button after setting.
1. Move the cursor to select “Ready Alarm”.
After selecting, press <ENT>.
2. ON and OFF will be switched alternately
if you press the <
↑
> or <
↓
> button.
3. Return to parameter setting display if you
press the <ENT> button after setting.
<↑>
<↓>
<ENT>
S l e e p T e m p
L o w Te m p
E r r o r A l a r m
200゚ C
150゚ C
ON
<↑>
<↓>
<ENT>
E r r o r A l a r m S e t
O F F
<↑>
<↓>
<ENT>
L o w Te m p
E r r o r A l a r m
Re a d y A l a r m
150゚ C
OFF
ON
<↑>
<↓>
<ENT>
Re a d y A l a r m S e t
O N