9
6. OPERATION
C.Temperature change method in
MANUAL mode
CAUTION
Be sure to insert the control card into the card slot and
set the mode to MANUAL before changing.
Setting change in temperature
CAUTION
The temperature setting range is 100 to 500°C (200 to
930°F).
Example: Change the temperature setting from
300 to 450°C.
1. Press the
button on the temperature
setting section for 1 sec. or more.
●
The HUNDREDS digit flashes on the
display, indicating that the HUNDREDS digit
can be entered.
2. Enter the HUNDREDS digit.
●
Use the
or
buttons to select your
desired value for the HUNDREDS digit.
When your desired value is displayed, press
the
button. The TENS digit begins to
flash.
3. Enter TENS digit.
●
Use the
or
buttons to select your
desired value for the TENS digit. When
your desired value is displayed, press the
button. The UNITS digit begins to flash.
4. Enter the UNITS digit.
●
Select your desired value for the UNITS
digit in the same manner as for the TENS
digit. When your desired value is displayed,
press the
button.
displays
and indicates that the temperature setting
procedure is completed.
CAUTION
If the power is turned OFF before the temperature set-
ting procedure is completed (
is not displayed),
the new setting value will not be stored in memory.
Press the
or
button.
Press the
button once.
Press and hold the
but-
ton for more than 1 second.
Press the
or
button.
Press the
button once
Press the
button once
●
Attempting to enter a value outside the setting
range will cause the display to begin flashing the
HUNDREDS digit again. Reenter a correct value.
●
Both the display temperature and the tempera-
ture setting are the temperature at the sensor.
(Even with the same temperature setting, the
temperature of the hot air differs depending on
the nozzle size.)