2. Setting the Temperature
The temperature range is from 120 to 1120℉. (50 to 600℃)
If you enter a value outside the temperature setting range, the display returns to
the hundreds digit, and you have to enter a correct value.
※
Preset mode
In addition to the procedure described above, HAKKO FR-811 includes a preset mode allowing
the selection of temperature from the options you define (up to 5 temperature settings can be
programmed).
Select the preset number with
The procedure for making changes to the preset temperatures is the same as the "2. Setting the
Temperature". Enter the parameter setting to change the mode.
(refer to the “8. PARAMETER SETTING” in page 26.)
3.
Offset temperature setting
Setting is available within the range of ±90°F (50°C)
CAUTION
If the total of a set value and an offset value exceeds 1120
℉ (600℃)
, the exceeding portion in
the offset value is not effective.
4. Timer setting
The timer range is from 001 to 999 sec and “---(∞)” .
5. Timer mode selection
Timer mode setting can be switched
between the Opened timing and the
Closed timing modes.
Opened timer
Count starts when the set temperature
reached
Closed timer
Count start from the start
6. Airflow setting
The air flow setting range is 001 to 100 (
%
).
Set in the following operation
Changes values and
the selected item
Enter
Selected position and
the preset number