Display in the MANUAL SET mode (when T31-01 is selected)
<01>
N
When
MANUAL SET
is selected
AUTO DETECT
MANUAL SET
OFF
<↑> <↓> <OK>
▲
<01>
<02>
<03>
<↑> <↓> <OK>
▲
5. OPERATION
TIP TYPE
The tip type (450°C or 400°C) is displayed.
When MANUAL SET is selected, the screen changes to the one as shown in the lower right figure. Select
an appropriate number according to the tip to be used. Then, the tip type 01 (450°C) or 02 (400°C) is
displayed so that the tip type is clearly known.
When AUTO DETECT is selected, the tip type (type 01 (450°C) or type 02 (400°C)) is automatically detected. The
following conditions are required to detect the tip type.
- The tip must be cold.
- The tip must be placed on the soldering iron stand.
When the tip is frequently changed between type 01 and
type 02, you can select AUTO DETECT. When you do not
need automatic detection because you use either type only,
you can select MANUAL SET. When you do not need any
display, you can select OFF. You can select any mode
depending on the usage.
6. PARAMETER SETTING
・
When SET is pressed
Various settings can be changed. After changing the setting, setting change is reflected by selecting SAVE
→ OK. To escape without setting change, select CANCEL. パスワードロックの設定を行なっている場合、
SET画面へ移行する前にパスワードの入力が必要となります。
Display in the AUTO DETECT mode (when T31-01 is selected)
01
N
DISPLAY
AUTO SLEEP
AUTO SHUTOFF
<↑> <↓> <OK>
The cursor moves by pressing the <
↑
> or <
↓
>
button. The following items are displayed in order.
・DISPLAY
・AUTO SLEEP
・AUTO SHUTOFF
・PASSWORD LOCK
・PROFILE
・ALERT TIME
・<SAVE>
・<CANCEL>
▲
NOTE:
When AUTO DETECT is selected, 01 or 02 is displayed only when the soldering iron is
placed on the stand.
Display
SET
DISPLAY
AUTO SLEEP
AUTO SHUT OFF
PASSWORD LOCK
PASSWORD*
PROFILE
STATION ID
PROFILE 1 (2)
USER NAME
SOLDER TYPE
ALERT TIME**
Display item
DISPLAY / AUTO SLEEP / AUTO SHUT OFF / PASSWORD LOCK / PROFILE / ALERT TIME
NORMAL / EXPAND / OFF
00 (OFF) / 01
〜
29 min
OFF / 30 min /60 min
ON / OFF
“A - Z” Select three letters
STATION ID / PROFILE 1 / PROFILE 2
“A - Z”, “0 - 9”, “.”, “-” and space. You can enter up to 14 letters.
USER NAME / SOLDER TYPE
“A - Z”, “0 - 9”, “.”, “-” and space. You can enter up to 14 letters.
“A - Z”, “0 -9”, “.”, “-” and space. You can enter up to 14 letters.
0
〜
9999 hours
Initial value
NORMAL
06 min
30 min
OFF
ー
ー
ー
ー
ー
ー
0
* Displayed only when PASSWORD LOCK ON is selected.
** CHG TIP will not be displayed when ALERT TIME is set to 0 . (See the ALERT TIME )
Display item and initial value of SET screen are as follows.