background image

1. Press and hold the        button for at least 

two seconds.

              is displayed. When you press the        

button, the display will move to the adjust mode.

2. Changing from              to             .

 The procedure for changing the value in 

adjustment mode is the same as setting the 

temperature in normal mode.

    Please refer to Section 5 - OPERATION.

3. Press the        button to exit the setting after 

changing the values.

● 

The tip temperature will be adjusted accordingly.

UP

ENTER

ENTER

Example : If the measured temperature is 380℃, and the set temperature is 400℃.

B. The preset mode

The HAKKO FX-889 has a preset mode that will allow the unit to store up to 5 preset temperatures you 

can change between instead of using the above normal mode. 
Initial preset temperatures

P1: 250℃ (482℉),  P2: 300℃ (572℉),  P3: 350℃ (662℉),  P4: 400℃ (752℉),  P5: 450℃ (842℉)
The initial number of active presets is set to 5 at the factory.

The default selected preset is set to P3 at the factory.
Example : Changing preset temperature from preset No.1 (250℃) to No.3 (350℃).

Heater control will begin with new preset temperature.
The procedure for making changes to the preset temperatures is the same with “A. Changing the set 

temperature” in 5. OPERATIONEnter the parameter setting to change the mode. (Please refer to [6. 

PARAMETER SETTING])

CAUTION

CAUTION

* How to distinguish between Temperature 

  Setting Mode and Adjustment Mode.

  The display differs in the temperature setting 

  and the adjustment mode.

In the Temperature

Setting Mode

In the Adjustment

Mode

Identification lamps are on

in the adjustment mode.

Please be sure to confirm the status of the 

identification lamps so that you do not enter

a value in the wrong mode.

NOTE:

During adjustment mode, the hundreds digit will

accept values from 0 through 6 if the temperature

is set to display in ℃, or the values 0 through 9

if the temperature is set to display in ℉.

*Preset selection screen

Be displayed
alternately.

Press the         button 

once.

UP

Press the         button 

twice.

UP

ENTER

Be displayed
alternately.

Press the         button 

once.

C. Performing the temperature adjustment

When replacing the iron, heater or tip, a temperature adjustment may be required.

Use adjustment mode to perform the temperature adjustment.

• Enter the observed value in the adjustment mode after the tip temperature stabilizes.

• The maximum single adjustment that can be made is ±150℃ (270℉) relative to the set temperature.

  If a larger adjustment is needed, make the first adjustment at the maximum value of 150℃ (270℉), 

then repeat the adjustment process.

• When a new soldering iron is used or insertion position is changed from A.IRON to B.IRON (and vice 

versa), temperature adjustment is always required. 

Summary of Contents for FX-889

Page 1: ...AKKO FX 8801 Soldering iron M HAKKO FX 8802 Soldering iron N2 Type HAKKO FX 8803 Soldering gun HAKKO FX 8804 SMD Hot tweezer HAKKO FX 8805 Soldering iron L When using the HAKKO FX 8803 FX 8804 please...

Page 2: ...Failure to comply with a CAUTION may result in injury to the operator or damage to the items involved To prevent accidents or damage to the HAKKO FX 889 be sure to observe the following Do not use the...

Page 3: ...irons simultaneously Attachment of the color bands to one of the soldering irons will help identify which soldering iron is connected to receptacle A IRON and B IRON 1 2 CAUTION Be sure the sponge is...

Page 4: ...nd current temperature will be displayed When the display stabilizes the LED heater lamp will begin to flash B After use Always clean the tip and coat it with fresh solder after use Refer to Tip Maint...

Page 5: ...se refer to 6 PARAMETER SETTING CAUTION CAUTION How to distinguish between Temperature Setting Mode and Adjustment Mode The display differs in the temperature setting and the adjustment mode In the Te...

Page 6: ...screen for each mode after entering the password Please change the setting for each mode according to the procedure Enter the parameter setting to change the mode Please refer to 6 PARAMETER SETTING...

Page 7: ...f selecting the partial choose whether or not the password function is needed when moving to the temperature setting mode the preset mode and the adjust mode and set the password Parameter entering mo...

Page 8: ...tion 1 Press the button to change the display to 2 If you press the button the display will move to the setting mode selection screen If you press the button The normal mode and The preset mode will b...

Page 9: ...ress the button 10 If you press the button after selecting the display will move to password setting screen 2 If you select Restricted the display will move to the following password setting screen If...

Page 10: ...p using the iron holder A B C Holder base Remove 7 MAINTENANCE Performing proper and periodic maintenance extends product life Efficient soldering depends upon the temperature quality and quantity of...

Page 11: ...ly There are two methods of testing the cord assembly 1 Turn the unit ON and set the temperature control knob to 480 Then bend the iron cord at various locations along its length including in the stra...

Page 12: ...the tip is not inserted properly If the sensor temperature falls below the difference between the current temperature setting and the low temperature alarm tolerance is displayed and the warning buzze...

Page 13: ...too low ACTION Increase the setting value CHECK Is the cord assembly broken ACTION If the cord assembly is broken replace the HAKKO FX 8801 CHECK Is the tip temperature too high ACTION Set an appropri...

Page 14: ...B3550 Item No 10 Part Name Power cord 3 wire cord American plug Power cord 3 wire cord but no plug Power cord 3 wire cord BS plug Power cord 3 wire cord European plug CE Power cord 3 wire cord BS plu...

Page 15: ...tem No 1 2 3 4 5 6 7 8 9 10 11 Part No B1785 B3469 B2022 B2032 A1560 B2028 B3470 B3471 B3467 B3468 Part Name Nut Tip enclosure Tip Nipple Grounding spring Heating element Terminal board Handle Handle...

Page 16: ...C T18 CF2 T18 C3 SHAPE 3C T18 CF3 T18 K SHAPE K T18 D08 SHAPE 0 8D T18 D12 SHAPE 1 2D T18 D16 SHAPE 1 6D T18 D24 SHAPE 2 4D T18 I SHAPE I Tinned on the soldering surface only Use only genuine Hakko so...

Page 17: ...Ground Chassis Ground Chassis Green Yellow Black Black Black Black White White White White Green Yellow Power receptacle Green Yellow Red Red Switch Black Red Switch Ground Chassis 1 5 4 2 3 P W B Re...

Page 18: ...OPMENT CO LTD TEL 2811 5588 FAX 2590 0217 http www hakko com hk E mail info hakko com hk SINGAPORE HAKKO PRODUCTS PTE LTD TEL 6748 2277 FAX 6744 0033 http www hakko com sg E mail sales hakko com sg Pl...