Case1 "S-E" appears on the display.
Causes
:
:
:
:
The heater or the sensor is switched off. Or the soldering iron is
faulty.
Countermeasures
:
:
:
:
Measure the resistance value in the soldering tip to see
if the heater or the sensor is switched off.
■
When the resistance value is not normal
The heater or sensor is switched off. Replace a defective soldering tip with a
new one.
■
When the resistance value is normal
The sleeve assembly and the connector assembly might be faulty. Replace
the faulty sleeve assembly and the connector assembly with new assemblies.
Or have the faulty soldering station, the sleeve assembly, the connector
assembly and the soldering tip repaired.
Contact the place of purchase near you and give them the part number
below if you purchase a new connector assembly.
Part number: FM2028-03 Connector assembly
Summary of Contents for FX-952