42
7. Operation (continued)
Program Edit Screen
The start point and end point cells and checkboxes can be set directly in the Program Edit Screen.
More detailed settings can be performed in the Point Edit Screen which can be called up by
double-tapping in the first column or in the STEP column.
(1)
Each horizontal row shows information for a single point.
(2)
X0, Y0, Z0, θ0
Shows the information for the soldering start point.
(3)
X1, Y1, Z1, θ1
Shows the information for the soldering end point.
(4) O:
If checked, indicates that the start point is an offset.
Z:
Checked when “Return to” is set to Z lift position.
P:
Shows the solder feed soldering condition number.
D:
If checked, indicates that the soldering mode is DS (drag soldering).
(5)
Shows indications for when I/O settings or individual point settings have been set. If all settings
have been set,
[IOCZSP]
will be shown. If no setting has been made for the corresponding
section, the character for that section will be replaced by
[*]
.
I:
Input setting
O:
Output setting
C:
Cleaning setting
Z:
Individual point Z axis lift setting
S:
Individual point speed setting
P:
Palletizing setting
(6) Update
Applies the changes to the program and saves it.